Page 23
Signal Handling
TM-6740GE Software
TABLE 2.
GPIO Look-Up Table Input Labels
Table 3, “GPIO Look-Up Table Output Labels,” shows which output labels carry the output signals.
TABLE 3.
GPIO Look-Up Table Output Labels
Input
Label
Signal
Description
I0
TTL_IN(EXT_TRIG)
TTL-input 0. Used for external trigger.
FDV
Internal signal. Frame Data Valid.
I1
TTL_IN(EXT_VD)
TTL-input 1. Used for external vertical drive.
LDV
Internal signal. Line Data Valid.
I2
CTRL2
Internal control signal.
TTL_IN(EXT_HD)
TTL-input 2. Used for external horizontal drive.
I3
CTRL1
Internal control signal.
TTL_IN(INT)
TTL-input 3. Used for external integration control.
I4
CAM_STROBE
Internal signal. Strobe Input.
PULSE_GEN3
Pulse Generator 3 signals go here.
I5
CTRL0
Internal control signal.
PULSE_GEN2
Pulse Generator 2 signals go here.
I6
PULSE_GEN1
Pulse Generator 1 signals go here.
N/A
I7
PULSE_GEN0
Pulse Generator 0 signals go here.
N/A
Output label
Signal
Description
Q0
TTL-OUT(STROBE)
Strobe output
Q1
N/A
Q2
N/A
Q3
N/A
Q4
EVINIT
Trigger
Q5
INTG_CON
Integration control
Q6
EXT_VD
Vertical Drive
Q7
EXT_HD
Horizontal Drive
Q8
pulse_trig1
Pulse Generator 1 gets its trigger here
Q9
pulse_trig0
Pulse Generator 0 gets its trigger here
Q10
pulse_trig3
Pulse Generator 3 gets its trigger here
Q11
pulse_trig2
Pulse Generator 2 gets its trigger here
Q12
N/A
Q13
N/A
Q14
TRIG
Trigger for camera’s internal frame grabber
Q15
RESV
Reserved