Page 47
Operation
TM-6740GE Hardware
8.6.2 Internal Shutter Speed Control
The video signal starts with internal VINIT. When the external VINIT pulse is applied, internal VINIT
is latched to HD and the internal VINIT is delayed to set up the shutter speed period. The shutter speed
is controlled by communication software. Video output timing starts right after the internal VINIT and
single shots, FDV is output at the internal VINIT timing.
EXT. VINIT
HD
INT. VINIT with shutter speed control
Discharge
Transfer Gate
FDV
Analog Video Sync
Exposure time set by shutter speed
Strobe
Summary of Contents for TM-6740GE
Page 2: ......
Page 7: ...vii 10 1Specifications 64 10 1 1 TM 6740GE Physical Dimensions 65 10 1 2 Spectral Response 66...
Page 8: ...Page viii...
Page 10: ...Page x...
Page 12: ...Page xii...
Page 79: ......