background image

 

AI-Vue Camera   

User Manual 

 

VS1NL70 8M / VS1NN60 2M 

VS6NLB0 8M / VS6NN60 2M 

VS1NN70 / VS1NNL0 / VS12110 2M 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © Ability Enterprise Co., Ltd. 

All rights reserved. 

User Manual 

Ver

02 

Summary of Contents for AI-Vue VS1NL70

Page 1: ...AI Vue Camera User Manual VS1NL70 8M VS1NN60 2M VS6NLB0 8M VS6NN60 2M VS1NN70 VS1NNL0 VS12110 2M Copyright Ability Enterprise Co Ltd All rights reserved User Manual Ver 02 ...

Page 2: ...11 4 Auto Logout 11 5 Auto play Policy 12 3 Live View 12 1 Overview 12 2 Microphone 12 3 Volume 13 4 Snapshot 13 5 Full Screen 14 6 Zoom In Zoom Out 14 7 Focus 15 8 Refresh Focus 15 4 Image Image Parameters 15 1 Image Adjustment 15 2 White Balance 16 5 Image Image Configs 16 6 Image Exposure Mode 17 1 Create a ROI Rectangle 17 7 Image Advanced Setting 18 1 Components 18 2 IR Cut Filter Removal ICR...

Page 3: ...Time Picker 26 10 System Stream Configs 26 1 Web Stream 26 2 Main Camera Stream 26 3 Second Camera Stream 27 11 System Privacy Mask 27 1 Mask Status 28 2 The Mask Rule 28 3 Priority of Overlay Mask 28 12 Overlay 29 1 Stamp 29 2 Overlay Preview 29 3 Basic Setting 29 4 Add Photo 30 5 Position 30 13 System Audio 30 1 Microphone 30 2 Speaker 31 3 Synchronized with The Live View 31 14 System Digital I ...

Page 4: ...ort 36 19 Notification Event Setting 36 1 Add New Event 36 2 Event List 37 3 Edit Event 37 4 Delete the Event 37 20 Notification Trigger Source 38 21 Notification Notify Setting 38 1 Notify Method 38 2 How to Add Audio 39 3 Test Serve 39 22 Storage 39 1 File List 40 2 Delete The Files 40 3 Download the Filet 40 4 Refresh 40 23 Administration 40 1 Firmware Update 40 2 Factory Reset 41 3 SSH Server ...

Page 5: ...ABILITY AI Vue Camera User s Manual 4 25 Log Out 43 ...

Page 6: ... of such devices is legal before installing this unit for its intended use 2 Regulatory Information FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules This device compiles with FCC Rules Part 15 Operation is subject to the following two conditions This device may not cause harmful interference and Thi...

Page 7: ...he input voltage should conform to IEC60950 1 standard SELV Safety Extra Low Voltage and the LPS Limited Power Source Refer to the appropriate documentation for detailed information DO NOT connect multiple devices to one power adapter to avoid over heating or fire hazards caused by overload Make sure the plug is properly connected to the power socket When used with Power over Ethernet PoE the Powe...

Page 8: ...word AbAi Camera1 DHCP is the default network setting of camera If routers fails to assign IP address by DHCP the network setting will change to static IPv4 IP address https 192 168 0 11 find the camera and Login the web browser with default account information and connect Camera 3 Multiple Camera Follow the instructions 1 to 2 in Single Camera Unless a router fails to aasign IP addresses by DHCP ...

Page 9: ...ult account information and connect camera Go to System then choose Network you can change the IP address for the camera Repeat this process until each camera has a unique IP address 2 Web Interface 1 Log In In web browser type the IP address of the Network Camera in address field can enter the Login Screen ...

Page 10: ...l function and bug fix only on Google Chrome STEP 1 Click Sign in to login the camera web interface STEP 2 Since your camera is used for the first time enter default user name as the user name and the password See section 2 1 instruction 2 for Default User Name Password STEP 3 At initial login to the device the user will must be register new account The default account cannot login after new accou...

Page 11: ...ng admin opuser users guest mysql administrator oracle Cannot be the same as registered account username Password Must be 5 to 16 characters including alphanumeric characters Cannot begin with numbers Cannot be single character only ex aaaaa Cannot be default bad usernames including admin opuser users guest mysql administrator oracle Cannot be the same as registered account username More Informati...

Page 12: ...or account opuser AbOp Camera1 Default user account users Edge Camera1 3 User Permissions for Web HTTPS Administrator can access all web camera resources User can see live view web page only Operator can access all network camera resource 4 Auto Logout For security reasons the web will automatically log out after you have been idle for 10 minutes 600 seconds The status of the reset counter is as f...

Page 13: ...nt according to video resolution on the LiveView The Tool Bar is hidden after idle for 3 seconds but it will be displayed when the mouse cursor moves on the screen The setting area is enable only while the schedule mode is in default mode Year All day and it will be the same of the all day in the advanced setting synchronously Except when disable state 2 Microphone The Microphone Button is only di...

Page 14: ...crophone volume in a range of 0 100 Default 50 3 Volume The volume slider is hidden and the last volume setting will be remembered when the Speaker button is inactive Default The volume slider is displayed when the Speaker button is active Drag the slider can adjust the Speaker volume in a range of 0 100 Default 50 4 Snapshot Click the Snapshot button will save current frame as a photo of the JPG ...

Page 15: ...ol Bar is hidden after idle for 3 seconds but it will be displayed when the mouse cursor moves on the full screen It supports wheel slide controls zoom in and out in following ways When the mouse is placed on a standard screen When the screen is full 6 Zoom In Zoom Out Only the Optical Zoom can be maintained when page is switched ...

Page 16: ...ue does not change when the button is clicked 8 Refresh Focus Press to refresh the camera focus which makes the camera to do zoom focus again 4 Image Image Parameters 1 Image Adjustment The adjusting result will be displayed on Image Parameters Viewer synchronously When the minimum or maximum value is reached the value does not change when the button is clicked ...

Page 17: ...rature can be set when Auto WB Mode is off The color temperature adjustment result should be displayed on viewer synchronously 5 Image Image Configs The rotate adjusting result will be displayed on viewer synchronously When the Power Line Frequency is auto the camera will detect the current environment is 50Hz or 60Hz and Exposure Time will change accordingly ...

Page 18: ...ate a ROI Rectangle It needs to create a rectangle for the metering range when using for the first time or without setting a ROI rectangle Click on the screen to create the range of ROI and display the border in Orange Click the delete button can delete the ROI rectangle The ROI Rectangle Rules The available frame size is from 150x150 pixels to 600x600 pixels Default 150x150 pixels It cannot be sc...

Page 19: ...er change the mouse cursor to Resize Cursor The rectangle can be resized to a desired rectangle by dragging the border The function can know the storage about storage for used capacity and total capacity 7 Image Advanced Setting While in advanced setting webpage the live view will be the result of applying all the settings which user is tuning The different settings according to different schedule...

Page 20: ...hen any exposure mode is manual disable HDR The maximum value must be equal to or bigger than the minimum value 4 Levels When the general settings is enable Digital WDR is On HDR is On Digital Noise Reduction is 3D NR Levels can set different levels of settings 5 Navigator Viewer All setting values will be used in the image preview and displayed in the navigation viewer Click the Full Screen butto...

Page 21: ...Continuous Auto Focus Manual Push Auto Focus can be chosen The MF Focus and MF Speed can be set when the focous mode is manual only There is no Push AF item in the drop down menu in All Day mode 7 Save Reset If there are any changes the Save and Reset button will be displayed ...

Page 22: ...cate or Cancel to leave The duplicate function can copy all settings and effects of other time type to this time tab The copied settings can be modified and unsaved changes will be discarded unless the save button is pressed When using duplicate to copy settings From Period Dawn Sunrise Day Dusk Sunset Night to All Day if the focus mode is Push AF it will be changed to CAF ...

Page 23: ...he default display of the time type will be different when switch the Year Season Switch Control Year All Day Season Period 4 Year Mode Month Bar The 12 months will be framed in white and you can set the time type All day Period of year when click the Month Bar area The mode will be changed immediately when the time type is changed Except for not click the OK button to close the dialog box The Sea...

Page 24: ...lick the OK button to close the dialog box Season Label Each label will be placed next to the start month in the season range The range of each season can be set 1 9 months and each of the remaining seasons will have at least one month The colors of the season range will be the same The Season Label can not be moved The season label can not be changed sort or deleted The time type and range in eac...

Page 25: ...ld be named with a prefix Backup_ and a date time suffix yyyyMMdd_HHmmss Ex Backup_20191010_080000 Show the notification when saved the file There are two ways to close the notification Click OK button After 3 seconds Restore Flow Chart Click Restore Button Loading File in File Open Window Start to Restore Wait for Upload Complete 3 Reboot Click Reboot button Click OK button to reboot or Cancel to...

Page 26: ... the SD Card Settings for Recording Capacity If the SD card capacity is less than 4096MB recording capacity setting will be disabled and recording function will also be disabled SD Card Re detect While camera reboot with SD card inserted or SD card is inserted while camera is running camera will detect the SD card capacity and the recording capacity setting may be changed automatically Keep the se...

Page 27: ...e Time Zone will be disabled when clock sync is PC Calendar In calendar click Left Right arrow should change the month and display corresponding dates of the month Click the digit of date should change the displaying date on Date Picker synchronously All clicks inside the calendar should keep the calendar display on screen Time Display time minute and second on the Time Picker Can be change the di...

Page 28: ...am only The Rate Control and GOP Length cannot be used when the stream format is MJPEG 11 System Privacy Mask Click Add Mask could add a mask on center of Setting Window The mask can be moved or overlapped using mouse cursor Up to 8 masks can be created If the mask has reached the maximum limit disable Add Mask until masks are less than 8 Default Color Black Mask Display Click the Switch Box to ac...

Page 29: ...Cursor In this situation the mask can be moved in the Setting Window and can be overlapped each other If the position where the Move Cursor hovers is overlapped by two or more frames only the uppermost frame can be controlled When the mouse cursor hovers over any part of mask border change the mouse cursor to Resize Cursor The mask can be resized to a desired rectangle by dragging the border The a...

Page 30: ... is block Both are displayed at the top of the view 3 Basic Setting Font Size Click the Select Box to drop down the Font Size list Small Medium Default and Large This setting should be kept and shared for all resolution Font Color There are a Color Patch and a Select Boxes on this field Click the Color Patch Default White to launch a Color Picker Note If the user clicks outside the color picker it...

Page 31: ... be fine tuned in different aspect ratio Position Rule If it is the same position on the Below please put the text string above the timestamp If it is the same position on the top please the text string below the time stamp Horizontal Layout When LiveView is Horizontally allow displaying the Date and Time Text String in the same position except for the Image The font position has a higher priority...

Page 32: ...ized with the Live View Page 14 System Digital I O 1 Digital Input When DI is disable No Event Normal State Setting Open Circuit Grounded Circuit Current State Open Circuit No Event Event Grounded Circuit Event No Event 2 Digital Output Current State DO Normal State Setting Open Circuit Grounded Circuit Event State Event DO Grounded Circuit DO Open Circuit No Event DO Open Circuit DO Grounded Circ...

Page 33: ...pe Change setting if necessary Click Save All Button Click OK to Save restart the network or Cancel to leave without changes The Dialog cannot be closed when restarting the network The progress bar and percentage are displayed to show the current progress When the camera network settings have been changed user may need to discover and connect camera again ...

Page 34: ...Size CA Certificate PEM DER 512KB Client Certificate PEM DER Client Private Key PEM DER PFX P12 After necessary files uploaded the 802 1X connection will still fail in the cases below Camera has corrupted file Not using correct files for 802 1X connection 2 Switch To EAP TLS Click Enable button All the necessary fields must be filed in All input boxes formatted correctly Click Save All button 3 Sw...

Page 35: ...l input boxes formatted correctly Click Save All button 4 Refresh There are two ways to update the file list a Click Refresh button b Re enter the IEEE 802 1X page 5 Reset Button The reset button is displayed when IEEE 802 1X is disabled only ...

Page 36: ...efault There are three types Device Log Access Log and Detection Log of log can be recorded 2 Log List Display the log according to the conditions made from Date Time in order The newest message will be displayed at the bottom Click the Refresh button should refresh the Log List ...

Page 37: ...ton After 3 seconds The List of Log Device Log Access Log Detection Log boot result user login Digital Input camera serial number user logout Motion Detection camera firmware version in use user login failed Tampering Detection camera program errors user block in blacklist AI Detection setting changes configuration backup configuration restore 19 Notification Event Setting All defined events will ...

Page 38: ...edule There are two time mode All Day Period for setting Only 1 mode can be set for each event setting If the Target Day and Target Time Slot are not set when the time mode is Period the OK will still disable to add new event End time must be greater than start time 2 Event List Select Individual Event double click to edit the event Select All Event The delete button is enabled when event is selec...

Page 39: ... AI Vue Camera User s Manual 38 20 Notification Trigger Source Each trigger source has a switch on right side Click the switch could enable or disable the trigger 21 Notification Notify Setting 1 Notify Method ...

Page 40: ...th 48kHz sampling rate Add Audio File Add by dropping file or clicking to upload The size should not exceed 1MB Complete setting of the audio as below Click OK to cancel the data transmission 3 Test Serve Click the Test Button to check the configuration of server and pop up a corresponding message Click OK to close the message Audio Playback Test If the test is successful the video file will be pl...

Page 41: ...ll Click Delete button Click OK to delete or Cancel to leave 3 Download the Filet Select file or select all Click Download button Start to download 4 Refresh After click the Refresh button on the Storage Page the current folder will remain on the same folder and the same number of pages There are two ways to update the file list Click Refresh button Re enter the Storage page 23 Administration 1 Fi...

Page 42: ... browser is closed Camera will reboot when completed 3 SSH Server The SSH default is enabled the default account is root and password is the same as default administrator See section 2 1 for Default User Name Password 4 Port The Internet Assigned Numbers Authority IANA suggests the range 49152 to 65535 215 214 to 216 1 for dynamic or private ports Please refer to https en wikipedia org wiki Epheme...

Page 43: ...ted user can only login SSH via public key After public key uploaded the SSH connection will still fail in the cases below Camera has corrupted public key file Not using paired key to connect to camera Upload The Public Key File Click Upload button Select the file to upload in a File Open Windows The file must be in correct format Upload file The network must be connected Click to cancel the actio...

Page 44: ...rm New Password Click Confirm New Password to delete only the text in the Confirm New Password 25 Log Out There are 6 ways to log out the Web Viewer In Device Page click Reboot could restart the camera In Administration Page click Reboot or Factory Reset could restart the camera Close the web browser should forcefully logout without displaying any message Power off the computer should forcefully l...

Reviews: