BalanceWhiteAuto
Off, Once, Preset5000K, Preset6500K, Preset7500K
Adjustment range
3000K 〜 9000K
12pin (DC IN/TRIG)
Input range: DC +10V 〜+ 25V
consumption: 9.3 W(typ.)
(at 12 V input, full pixel, Default setting, Environmental
temperature 25°C) (Typical)
14.7 W
(Maximum)
RJ-45
Ethernet standards and the cable type and the maximum cable length.
1000 Base-T : Cat5e, Cat6, Cat6e, Cat6A, Cat7
2.5G Base-T : Cat5e, Cat6, Cat6e, Cat6A, Cat7
5G Base-T : Cat6, Cat6e, Cat6A, Cat7
10G Base-T : Cat6*, Cat6e*, Cat6A, Cat7
*) The maximum cable length is limited to 55m.
12pin (DC IN/TRIG)
Model : HR10A-10R-12PB(71) (or equivalent)
Function: Power supply input / External trigger / External I/O
10pin (AUX)
Model
Camera side:Equivalaent to Hirose Electronic 3260-10S3 (55)
Cable side :Equivalaent to Hirose Electronic 350-10P-C (50)
Function: External tigger / External I/O
LED (Power/TRIG)
Function:Power on, trigger input indicator
PRNU
DSNU
Post-correction: Within ±1% (during 100% output)
Post-correction: Within ±5% (during 0% output)
Test pattern
Available : Off、White、GrayPattern1(Ramp)、GrayPattern2(Stripe)、ColorBar
Dimensions
White balance
Flange back
M42 mount: 16 mm (in air), tolerance: 0 mm to –0.05 mm
F mount: 46.5 mm,
tolerance: 0 mm to –0.05 mm
Connectors / LEDs
Image porcessing
1 Pixel sensitivity correction: Pixel correction (DSNU, PRNU)
2 Shading correction: ColorShading, FlatShading
3 LUT: OFF: γ=1.0, ON: 257 points can be set
4 Gamma: 0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8, 0.9, 1.0 (9 steps available)
Power supply voltage
Lens mount
M42 mount, F mount
Standard compliance
Weight
5℃〜+ 45℃ / 20%〜 80%
(non-condensing)
25℃〜+ 60℃ / 20%〜 80%
(non-condensing)
10G(20 Hz 〜 200 Hz X-Y-Z direction)
80G
CE(EN61000-6-2 and EN61000-6-3), FCC part 15 class B, RoHS, WEEE, KC
62 × 62 × 102.3 mm (WHD; excluding mount and protrusions)
M42 mount : 340 g (typ.) F mount : 410 g (typ.)
Storage temperature / humidity
Operating temperature / humidity
Vibration resistance
Impact resistance
SW-4000TL-10GE
— 57 —
Package contentsCamera
body (1)
Sensor protection cap (1)
Dear Customer (sheet) (1)
Design and specifications are subject to change without notice.
Approximately 30 minutes of warm-up are required to achieve these specifications.
About the verified performance temperature
Make sure the following temperature conditions are met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 100 °C or less during
operation.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.
Caution
Summary of Contents for SW-4000TL-10GE
Page 58: ...SW 4000TL 10GE 58 Spectral Response Wave length nm Relative Response ...
Page 59: ...SW 4000TL 10GE 59 Dimensions F mount SW 4000TL 10GE F Dimenstional tolerance 0 3mm Unit mm ...
Page 60: ...SW 4000TL 10GE 60 M42 mount SW 4000TL 10GE M42 Dimenstional tolerance 0 3mm Unit mm ...
Page 64: ...SW 4000TL 10GE 64 Revision Date Changes Revision history 1 0 Apr 2019 First version ...