Setting value /
selectable range
Description
Counter 0 ~ 5
Select the counter.
CounterEventSource
Counter0
Off, Line Trigger
Counter1
Off, Line Start
Counter2
Off, Exposure Start
Counter3
Off, Frame Trigger
Counter4
Off, Frame Start
Counter5
Off, Frame Transfer End
Select the counter event signal
for which to read the count
value.
When set to Off, the counter
operation will stop (but will not
be reset).
CounterEventActivation Counter0 Rising Edge
Counter1 Rising Edge
Counter2 Rising Edge
Counter3 Rising Edge
Counter4 Rising Edge
Counter5 Falling Edge
Specify timing at which to count.
(This setting is fixed.)
Item
Counter 0 ~ 5
SW-4000TL-10GE
— 36 —
■
Internal camera blocks
Event detection
Counter
At event occurrence or count up
Counter
At event occurrence or count up
Counter
At event occurrence or count up
Counter
At event occurrence or count up
Counter reset
Read requested counter value
Internal MCU of camera
Send information
to the HOST
Event detection
Event detection
Event detection
Counter0
Line Trigger
Counter1
Line Start
Counter2
Exposure Start
Counter5
Frame Transfer End
・
・
・
■
To use the counter function
Configure the settings as follows.
Six counters are available. Specify a counter (Counter0 to Counter5), and configure the
settings.
Summary of Contents for SW-4000TL-10GE
Page 58: ...SW 4000TL 10GE 58 Spectral Response Wave length nm Relative Response ...
Page 59: ...SW 4000TL 10GE 59 Dimensions F mount SW 4000TL 10GE F Dimenstional tolerance 0 3mm Unit mm ...
Page 60: ...SW 4000TL 10GE 60 M42 mount SW 4000TL 10GE M42 Dimenstional tolerance 0 3mm Unit mm ...
Page 64: ...SW 4000TL 10GE 64 Revision Date Changes Revision history 1 0 Apr 2019 First version ...