SW-4000TL-10GE
— 33 —
Variable Line Rate
You can set the line rate to 1L or more. This function can be used to match the scanning
speed of the camera to the feeding speed of the object or to lengthen the accumulation time
to increase sensitivity.
• Variable range: RGB8
66Hz*
~
66kHz
*) When taking a trigger signal from the outside, there is no limitation on the minimum value.
• Variable unit: 0.1 Hz
• Supported operation modes: Exposure Mode OFF / Trigger OFF
Exposure Mode Timed / Trigger OFF
◇
You can also save the setting and have it applied whenever the power is subsequently
turned on, but this requires additional operations.
◇
Switching and settings storage for this function is performed via serial communication.
◇
The black level will change depending on the line rate, so be sure to readjust the black
level after changing the line rate or trigger period.
EEN (Exposure Enable) Function
Perform external output for the timing at which video is accumulated to the sensor.
The signal is output to the DC IN / TRIG IN connector (12-pin round) or AUX connector.
Example: Output to DC IN/TRIG IN connector (12-pin round)
Trigger
Exposure
EEN
( Internal / External )
Test Pattern Function
You can display the following types of test patterns (Off, White, GrayPattern1, GrayPattern2,
ColorBar). Video output is not possible while a test pattern is being executed. This function is
not dependent on gain and offset values that have already been configured.
◇
This function cannot be saved as the initial state of the camera.
Electronic Shutter
When you use this function, you can set the exposure to a preconfigured accumulation time,
regardless of the line rate.
• Variable range: 3 μs to 15.149 ms
• Variable unit: 0.01 μs (1clk)
• Supported operation modes: When Trigger Mode ON, Exposure Mode Timed
◇
You can also save the setting and have it applied whenever the power is subsequently
turned on, but this requires additional operations.
In “Trigger Mode OFF, Exposure Mode Timed” mode, the line rate configured will be the
maximum value at which the shutter operates. However, in “Trigger Mode ON, Exposure Mode
Timed” mode, the input trigger period will be the maximum value.
Caution
Summary of Contents for SW-4000TL-10GE
Page 58: ...SW 4000TL 10GE 58 Spectral Response Wave length nm Relative Response ...
Page 59: ...SW 4000TL 10GE 59 Dimensions F mount SW 4000TL 10GE F Dimenstional tolerance 0 3mm Unit mm ...
Page 60: ...SW 4000TL 10GE 60 M42 mount SW 4000TL 10GE M42 Dimenstional tolerance 0 3mm Unit mm ...
Page 64: ...SW 4000TL 10GE 64 Revision Date Changes Revision history 1 0 Apr 2019 First version ...