Item
Setting value / selectable range
Trigger Mode
On
Trigger Selector
Line Start
Trigger Source
Any
Trigger Activation
LevelHigh
(high-level duration)
,
LevelLow
(low-level duration)
Exposure Mode
TriggerWidth
(control via trigger width)
Item
Setting value / selectable range
Trigger Mode
On
Trigger Selector
Line Start
Trigger Source
Any
Trigger Activation
Rising Edge
(rising edge of input signal)
,
Falling Edge
(falling edge of input signal)
Exposure Mode
Timed
(control via exposure time)
Exposure Time
Varies depending on settings.
SW-4000TL-10GE
— 17 —
Step 5 Configuring Basic Settings for the Camera
1
Set [Exposure Mode] to [Timed].
2
Specify the exposure time in [Exposure Time].
3
Set [Trigger Mode] to [On] and set [Trigger Selector] to [Line Start].
4
If necessary, change the [Trigger Source], and [Trigger Activation] settings.
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
■
Control via External Triggers
When Controlling the Exposure Time Using the Pulse Width of the Trigger
Input Signal
Configure the settings as follows.
1
Set [Trigger Mode] to [On] .
Because this camera automatically performs several correction functions at startup, the first
three lines captured after powering on or resetting the camera will contain incorrect data.
To ensure accuracy, you should not use the first three lines acquired after any power-up or
reset.
Caution
Summary of Contents for SW-4000TL-10GE
Page 58: ...SW 4000TL 10GE 58 Spectral Response Wave length nm Relative Response ...
Page 59: ...SW 4000TL 10GE 59 Dimensions F mount SW 4000TL 10GE F Dimenstional tolerance 0 3mm Unit mm ...
Page 60: ...SW 4000TL 10GE 60 M42 mount SW 4000TL 10GE M42 Dimenstional tolerance 0 3mm Unit mm ...
Page 64: ...SW 4000TL 10GE 64 Revision Date Changes Revision history 1 0 Apr 2019 First version ...