5.4.9 Pulse Generator Clear Source
The following clear sources can be selected as the pulse generator clear signal.
Table - 13
Pulse generator clear source
5.4.10 Pulse Generator Inverter
Clear Source Signal can be have polarity inverted.
Pulse Generator
Clear Source
item
Description
Low
Connect Low level signal to Clear Source for the selected pulse generator.
Default setting
High
Connect High level signal to Clear Source for the selected pulse generator.
Frame Trigger Wait
Connect Frame Trigger Wait signal to Clear Source for the selected pulse generator.
Frame Active
Connect Frame Active signal to Clear Source for the selected pulse generator.
Exposure Active
Connect Exposure Active signal to Clear Source for the selected pulse generator.
Acquisition Trigger wait
Connect Acquisition Trigger Wait signal to Clear Source for the selected pulse generator.
Acquisition Active
Connect Acquisition Active signal to Clear Source for the selected pulse generator.
FVAL
Connect FVAL signal to Clear Source for the selected pulse generator.
PulseGenerator0 Out
Connect Pulse Generator 0 output to Clear Source for the selected pulse generator.
PulseGenerator1 Out
Connect Pulse Generator 1 output to Clear Source for the selected pulse generator.
PulseGenerator2 Out
Connect Pulse Generator 2 output to Clear Source for the selected pulse generator.
PulseGenerator3 Out
Connect Pulse Generator 3 output to Clear Source for the selected pulse generator.
User output0 Out
Connect User output 0 to Clear Source for the selected pulse generator.
User output1 Out
Connect User output 1 to Clear Source for the selected pulse generator.
User output2 Out
Connect User output 2 to Clear Source for the selected pulse generator.
User output3 Out
Connect User output 3 to Clear Source for the selected pulse generator.
TTL 1 In
Connect TTL 1 In signal to Clear Source for the selected pulse generator.
OPT 1 in
Connect Opt 1 In signal to Clear Source for the selected pulse generator.
CXP (Trigger packet In)
Connect Trigger packet In signal to Clear Source for the selected pulse generator.
Nand 0 Out
Connect NAND 0 output signal to Clear Source for the selected pulse generator.
Nand 1 Out
Connect NAND 1 output signal to Clear Source for the selected pulse generator.
TTL 2 In
Connect TTL 2 In signal to LINE 10.
LVDS 1 In
Connect LVDS 1 In signal to Line 11
Note:
The pulse generator output cannot be used as the clear input to the same pulse generator. Refer to
“
5.3.6.2.
Table 8
”
.
(Example 2) Clear Activation = Rising Edge, Clear Sync Mode = Sync Mode,
Clear Inverter = False
Pulse
Generator
Output
Pulse
Generator
Clear Source In
0
Pulse
Generator
Length
0
Clear
↓