— 55 —
GO-5100MP-USB
Pulse Generator Clear
Activation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Off
Set the clear signal condition for the count
clear input of the pulse generator.
Pulse Generator Clear Source
Low,
High,
Acquisitiion Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
LVAL,
User Output 0
User Output 1
Line5 - Opt In 1
NAND0 Out
NAND1 Out
Low
Select the count clear input signal source.
Pulse Generator Clear Inverter True, False
False
Select whether to invert the polarity of the
count clear input signal.
Pulse Generator Clear Sync
Mode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.