LUT (Lookup Table)
Related Setting Items:
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 257 setting
points (indexes).
To Use the LUT Function
Configure the settings as follows.
Item
Setting Value /
Selectable Range
Description
JAI LUT
Mode
LUT
Use LUT.
LUT
Selector
(Color
models
only)
Mono Model:
Mono
Color Model: Red,
Green, Blue
Select the LUT channel to control.
LUT Index 0 ~ 256
Select the LUT index to configure. Indexes represent the possible pixel values
captured on the sensor, from the lowest value (Index 0) to the highest (Index
256). For example, Index 0 represents a full black pixel and Index 255
represents a full white pixel.
LUT Value 0 ~ 4095
Set the LUT output value for the selected index.
LUT Values
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate
LUT values between the index points.