GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Main Functions
- 47 -
Pixel Format
Binning Settings
Height Width
H Period
Pack Value
Frame Rate (fps)
10 bit / 12bit*
1 x 1 (Full ROI)
2056
2464
26.343 μs
16
11.3
2 x 1
1028
2464
18.1
1 x 2
2056
1232
35.6
2 x 2
1028
1232
35.5
10 bit Packed / 12bit*
1 x 1 (Full ROI)
2056
2464
26.343 μs
12
15.1
2 x 1
1028
2464
30.2
1 x 2
2056
1232
18.1
2 x 2
1028
1232
35.5
The values during [Continuous]
Note:
*12-bit binning is not supported.
Caution:
Although the maximum frame rate value is determined by the GigE bandwidth range,
when ROI is configured, the frame rate cannot exceed the sensor output's allowable frame rate
value.
Exposure Mode
Related Setting Items:
The following exposure modes are available on the camera.
Exposure
Mode
Setting
Exposure Operation
OFF
Exposure control is not performed (free-running operation).
Timed
Mode in which control is performed using exposure time. Acquire images using an exposure time
configured beforehand on an external trigger.
Trigger
Width
Mode in which control of the exposure time is performed using the pulse width of the trigger input
signal. The exposure time will be the same as the pulse width of the trigger input signal. This
allows long exposure.
Note:
The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in “
Configure Exposure and External Trigger Settings
”.