83
̶
GO-2400M-PMCL / GO-2400C-PMCL
SequenceMode
GainBlue1
R/W
SQPGB1
Min to Max
–4533
17713
0
SQPGB1=[Param.]<CR><LF>
SQPGB1?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index1.
SequenceMode
GainBlue2
R/W
SQPGB2
Min to Max
–4533
17713
0
SQPGB2=[Param.]<CR><LF>
SQPGB2?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index2.
SequenceMode
GainBlue3
R/W
SQPGB3
Min to Max
–4533
17713
0
SQPGB3=[Param.]<CR><LF>
SQPGB3?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index3.
SequenceMode
GainBlue4
R/W
SQPGB4
Min to Max
–4533
17713
0
SQPGB4=[Param.]<CR><LF>
SQPGB4?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index4.
SequenceMode
GainBlue5
R/W
SQPGB5
Min to Max
–4533
17713
0
SQPGB5=[Param.]<CR><LF>
SQPGB5?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index5.
SequenceMode
GainBlue6
R/W
SQPGB6
Min to Max
–4533
17713
0
SQPGB6=[Param.]<CR><LF>
SQPGB6?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index6.
SequenceMode
GainBlue7
R/W
SQPGB7
Min to Max
–4533
17713
0
SQPGB7=[Param.]<CR><LF>
SQPGB7?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index7.
SequenceMode
GainBlue8
R/W
SQPGB8
Min to Max
–4533
17713
0
SQPGB8=[Param.]<CR><LF>
SQPGB8?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index8.
SequenceMode
GainBlue9
R/W
SQPGB9
Min to Max
–4533
17713
0
SQPGB9=[Param.]<CR><LF>
SQPGB9?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index9.
SequenceMode
GainBlue10
R/W
SQPGB10
Min to Max
–4533
17713
0
SQPGB10=[Param.]<CR><LF>
SQPGB10?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index10.
:
SequenceMode
GainBlue128
R/W
SQPGB12
Min to Max
–4533
17713
0
SQPGB128=[Param.]<CR><LF>
SQPGB128?<CR><LF>
(Color model only)
Set the blue gain
of Sequence Roi
Index128.
CommnadSequence
Index
R/W
CSQI
Same as
SequenceModeIndex
1
128
0
CSQI=[Param.]<CR><LF>
CSQI?<CR><LF>
Set the index to
execute during
Command
Sequence Mode.
CurrentSequence Index R/O
SQIDX
Same as
SequenceModeIndex
1
128
0
SQIDX?<CR><LF>
Display the index
number of the
current Command
Sequence Index.
SequenceReset
W/O
SQRST
0
0
0
0
SQRST=[Param.]<CR><LF>
Reset the current
index number for
Trigger Sequence
Mode and
Command
Sequence Mode
to “Index 1.”
SequenceLutMode
R/W
SQLUT
0: Gamma
1: LUT
0
1
0
SQLUT=[Param.]<CR><LF>
SQLUT?<CR><LF>
Select the LUT
mode to use
during Trigger
Sequence Mode
and Command
Sequence Mode.
(This setting is
applied when
Sequence Roi Lut
Enable is set to
“True.”)
SensorMultiRoiWidth1
R/W
SMRW1
Min to Max
16
1936
1936
SMRW1=[Param.]<CR><LF>
SMRW1?<CR><LF>
Set the width of
Sensor Multi Roi
Index1.
SensorMultiRoiWidth2
R/W
SMRW2
Min to Max
16
1936
1936
SMRW2=[Param.]<CR><LF>
SMRW2?<CR><LF>
Set the width of
Sensor Multi Roi
Index2.
SensorMultiRoiWidth3
R/W
SMRW3
Min to Max
16
1936
1936
SMRW3=[Param.]<CR><LF>
SMRW3?<CR><LF>
Set the width of
Sensor Multi Roi
Index3.