31
̶
GO-2400M-PMCL / GO-2400C-PMCL
■
1X8-1Y (CL)
1X8-1Y (CL) is a 8-tap output format as defined in GenICam tap geometry.
■
Cable length reference
The following is a reference for the length of cable you can use based on the Camera Link clock*
1
.
CL Pixel Clock [MHz]
CL cable length
37.125
10 m
74.25
7 m
84.85
3 m
*1 The length of cable you can use will also vary depending on type and maker.
Acquisition Control (Image Acquisition Controls)
Perform operations and configure settings related to image capture in [Acquisition Control].
On the GO-2400-PMCL, acquisition control always operates in [Continuous] mode.
Changing the Frame Rate
When [Trigger Mode] is disabled, you can change the frame rate in [Acquisition Frame Rate].
Note
•
The shortest frame period varies depending on the ROI, pixel format, and binning mode selected. The longest
frame period is 0.125 Hz (8 sec.).
•