EL-2800M-USB / EL-2800C-USB
- 44 -
7.6. Trigger width mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure
times are supported. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
Primary settings to use this mode
Exposure mode: Trigger width
Trigger mode: ON
Frame Start: ON
Table – 22 Minimum interval of the trigger pulse (Sensor Tap Geometry: 1X2 – 2YE)
Readout mode
FULL
2/3 AOI 1/2 AOI 1/4 AOI 1/8 AOI
1/2V
Binning
(Note1)
Minimum
interval
lines
746
566
476
341
274
377
Note 1) EL-2800M only
Note 2) This table shows in case of Trigger option being set to Readout. If Trigger
option is set to OFF, this period is longer than the figures in this table.
7.6.1 If the overlap setting is “OFF”
Fig.35 Overlap = OFF
Trigger
CCD
Exposure
FVAL
Exposure
Active
Exposure Period
t3
t1
t2
t4
t1
t2
t3
t4
1L (Min)
424 clk
4.5L
~
5.5L
8
µ
s