EL-2800M-USB / EL-2800C-USB
- 20 -
Fig.10
Counter clear in Sync mode
5.6.9 Pulse Generator Clear Source
The following sources can be selected as the pulse generator clear signal.
Table - 12
Pulse generator clear source
Pulse Generator
Clear Source
item
Description
Low
Connect Low level signal to Clear Source for the selected pulse generator.
Default setting
High
Connect High level signal to Clear Source for the selected pulse generator.
Frame Trigger Wait
Connect Frame Trigger Wait signal to Clear Source for the selected pulse
generator.
Frame Active
Connect Frame Active signal to Clear Source for the selected pulse generator.
Exposure Active
Connect Exposure Active signal to Clear Source for the selected pulse
generator.
Acquisition
Trigger
Wait
Connect Acquisition Trigger Wait signal to Clear Source for the selected pulse
generator.
Acquisition Active
Connect Acquisition Active signal to Clear Source for the selected pulse
generator.
FVAL
Connect FVAL signal to Clear Source for the selected pulse generator.
LVAL
Connect LVAL signal to Clear Source for the selected pulse generator.
PulseGenerator0 Out
Connect Pulse Generator 0 output to Clear Source for the selected pulse
generator.
PulseGenerator1 Out
Connect Pulse Generator 1 output to Clear Source for the selected pulse
generator.
TTL 1 In
Connect TTL 1 In signal to Clear Source for the selected pulse generator.
Opt 1 In
Connect Opt 1 In signal to Clear Source for the selected pulse generator.
NAND 0 Out
Connect NAND 0 output signal to Clear Source for the selected pulse generator.
NAND 1 Out
Connect NAND 1 output signal to Clear Source for the selected pulse generator.
Line 10
TTL 2 In
Connect TTL 2 IN signal to LINE 10.
Line 11
LVDS 1 In
Connect LVDS 11 1 IN signal to Line 11
Note:
The pulse generator output cannot be used as the clear input to the same pulse generator. Refer to
“
5.4.7.2 GPIO matrix table
”
.
(Example2) Clear Activation = Rising Edge, Clear Sync Mode = Sync Mode,
Clear Inverter = False
Pulse
Generator
Output
Pulse
Generator
Clear Source In
0
Pulse
Generator
Length
0
Clear
↓
Note: Repeat Count is also reset.