CM-140 GE / -RA/-UV / CB-140GE/-RA
- 45 -
10.2.2.1 LVAL_sync timing
TRIG
2L (min)
LVAL
1L(max)
CCD Exposure
EEN
Exposure Time
2L
FVAL
When trigger is input during FVAL HIGH,
LVAL sync Mode is set.
GE:(Full:61us Vbinnig:78us)
UV:(Full:117.8us Vbinnig:149.6us)
Fig. 28 Edge Pre-select LVAL sync Timing
10.2.2.2 LVAL_async timing
TRI G
EEN
FAVL
2L
~
3L
Full:61us
~
92us Vbinnig:78us
~
116us)
2L (min.)
GE:7.83µs ± 1µs
UV:15.66µs ± 1µs
UV: Full:
117.86µs
~176.7
µs, V Binning 149.6µs
~224.4
µs
GE:
CCD exposure
Exposure time
When the trigger is input while FVAL is LOW,
the accumulation is LVAL async mode.
Fig.29
Edge Pre-select LVAL async Timing