CM-140 GE / -RA/-UV / CB-140GE/-RA
- 11 -
4.2. CM/CB-140GE-RA
Lens mount
C-mount (Note *1)
CCD sensor
1/3 inch CCD sensor
12-pin connector
DC +12V to +24V power and GPIO interface
RJ-45
Gigabit Ethernet connector with threaded holes for
thumbscrews
LED
Indication for power and trigger input
LED
GigE Network condition: LINK
LED
GigE Network condition: ACT
Holes for RJ-45 thumbscrews
When an RJ-45 connector with thumbscrews is used,
remove the two screws located above and below the
Ethernet connector (Note*2)
Mounting holes
M3 depth 3.5mm for tripod mount plate (Note*3)
*1) Note: Rear protrusion on C-mount lens must be less than 10.0mm.
*2) Note: When a RJ-45 cable with thumbscrews is connected to the camera, please do not
excessively tighten screws by using a screw driver. The RJ-45 receptacle on the camera
might get damaged. For security, the strength to tighten screws is less than 0.147
Newton meter (Nm). Tightening by hand is sufficient in order to achieve this.
*3) Note: The depth of holes is 3.5mm. When the tripod adapter plate MP-40 or MP-41 is used, use
the attached screws. If installing the camera directly, please do not use screws longer
than 3.5mm.
Fig.2 Locations (CM-140GE-RA / CB-140GE-RA)
Seri
al No
.
Caut
ion s
eal
GigE
POW
ER /
TRIG
FCC
seal
①
②
③
④
⑤
⑥
⑦
⑧
⑧
⑨