AM-800GE / AB-800GE
- 85 -
Single Frame:
If the trigger is input, only one frame is captured and after the
completion of capturing, the acquisition is automatically stopped.
Multi Frame:
If the trigger is input, frames which are set by Acquisition Frame
Count are captured and after the completion of capturing, the
acquisition is automatically stopped.
Trigger Selector
Trigger Selector includes Acquisition Start and Acquisition End commands which
determine the start point and end point of acquisition, and Trigger commands
which set the trigger timing.
Acquisition Start has ON or OFF setting. Refer to chapter 9.1 for the details.
ON:
In this case, if Acquisition Start Trigger is applied, the status is waiting the
trigger input.
The acquisition starts in the order of Acquisition start Trigger input and Trigger
signal input.
OFF: In this case, the camera runs freely. If the trigger signal is input, the
acquisition starts immediately.
Trigger setting
Select from Frame Start, Exposure Start, Exposure End and JAI
Acquisition Transfer
Start and set the details.
Frame Start:
The exposure starts at the point of frame start.
JAI Acquisition Transfer Start :
This command makes the delayed readout from the
camera effective.
Exposure Mode setting
Timed :
The exposure is effective only for setting duration.
Trigger Width :
The exposure time is equal to the trigger width.
Summary of Contents for AB-800GE
Page 97: ...AM 800GE AB 800GE 94 b Image Format Control c Acquisition Control d Digital IO Control...
Page 98: ...AM 800GE AB 800GE 95 e Counter And Timer Control f Event Control...
Page 99: ...AM 800GE AB 800GE 96...
Page 100: ...AM 800GE AB 800GE 97 g Analog Control h LUT Control i Transport Layer Control...
Page 101: ...AM 800GE AB 800GE 98 j User Set Control k Action Control l JAI Custom Control...
Page 102: ...AM 800GE AB 800GE 99...