background image

 

CONTENTS 

 

Part 

I

 

 

Preparations before Usage 

1-1. Precautions before Usage……………………… 

1-2. Specifications and Characteristics… 

 

 

Part 

II

 

 

Product Introduction & Installation 

2-1. Main Functions Introductions……………….…… 

2-2.Connection Between Display and Load Cell ……….…

2-3.Keypad Function and Panel Indication…………… 

 

 

 


 

Part 

III

 

 

Setting of Weighing Capacity & Accuracy 

3-1.Setting Operation……………………….………… 

3-2.Relation  Between  LOAD-CELL  Output  &  Input 

Sensitivity……

 

 

 

Part 

IV

 

 

Setting of Functional Parameters 

4-1.Enter into Parameter Setting…………….………… 

4-2.Description of Functional Parameters.…………

 

 

 

10 

 

11 

 

PAGE   

                                                                                               

JADEVER

   

 

http:www.jadever.com.tw

 

0

 

Summary of Contents for JWI600

Page 1: ...ions 2 2 Connection Between Display and Load Cell 2 3 Keypad Function and Panel Indication 3 4 5 Part III Setting of Weighing Capacity Accuracy 3 1 Setting Operation 3 2 Relation Between LOAD CELL Output Input Sensitivity 7 9 Part IV Setting of Functional Parameters 4 1 Enter into Parameter Setting 4 2 Description of Functional Parameters 10 11 PAGE JADEVER http www jadever com tw 0 ...

Page 2: ...0 20 21 22 Part VI Single Point Weight Calibration 23 Part VII Error Message Simple Troubleshooting 24 Part VIII External Interface 8 1 RS 232 RTC board output pin 8 2 Option Output 8 2 1 Printer Output 8 2 2 PC Output 8 3 RS 232 Output Format 8 4 RS 232 Input Format 25 26 27 21 29 33 34 34 35 35 Part XI Appendix 1 Installation of Upright Pole 2 Unit Conversion Table 3 Optional Accessories 36 37 3...

Page 3: ...allation site Avoid an operation environment where the scale will be exposed to strong wind vibration and electromagnetic wave e g air inlet of air conditioner or fan or near heavy duty machines Please select an environment where the temperature is maintained within 0 40 avoid drastic temperature change 15 minute preheating is required before usage Please select 110 240 VAC 10 50 60HZ 6V4Ah BATTER...

Page 4: ...rtup and close function selection c It is allowed to select and set sampling filter speed depending on different application conditions d Weight checking function it will give sound alarm once the required package quantity is reached e Tare f Pre tare g Automatic tare h Automatic zeroing i Weight accumulation 2 Touch key with good feel enables easy operation Dust cover ensures nice look 3 HTN LCD ...

Page 5: ... E 2 E 3 S 4 S LOAD CELL CONNECTION 5 SHIELD Solution to overlarge LOAD CELL output Solution to oversmall LOAD CELL output 50k 500k ohm Add resistance LOAD CELL S S E E Add resistance S E E S LOAD CELL 50k 500k ohm PAGE JADEVER http www jadever com tw 4 ...

Page 6: ...ght symbol auxiliary unit Unit for simple counting and percentage kg unit Indicates steady usage M Accumulation symbol Negative symbol NET Net weight symbol ZERO Zeroing symbol Low battery power indication upper limit OK and lower limit weight checking mode PAGE JADEVER http www jadever com tw 5 ...

Page 7: ...nter into weight checking value setting unit shift Pre tare Accumulate Accumulation display Accumulation clearing digit plus 1 digit displacement Function selection enter into setting mode exit setting mode indicates press down the key once Part III Setting of Weighing Capacity Accuracy PAGE JADEVER http www jadever com tw 6 ...

Page 8: ...capacity Press the key to cyclically select the weighing capacity After selection it is allowed to begin step 4 directly or freely set the weighing capacity according to the following operation Press the key till the screen displays the right figure Press the key as shown at the right figure the last zero is flashing it is time to freely set the weighing capacity 3 Press the key the flashing digit...

Page 9: ... 1 500 600 1 600 1 300 800 1 800 1 400 1 000 1 1000 1 500 1 200 1 1200 1 600 1 500 1 1500 1 800 1 300 2 000 1 2000 1 1000 1 400 2 500 1 2500 1 1250 1 500 3 000 1 3000 1 1500 1 600 1 300 4 000 1 4000 1 2000 1 800 1 400 5 000 1 5000 1 2500 1 1000 1 500 6 000 1 6000 1 3000 1 1200 1 600 1 300 8 000 1 8000 1 4000 1 1600 1 800 1 400 10 000 1 10000 1 5000 1 2000 1 1000 1 500 12 000 1 12000 1 6000 1 2400 ...

Page 10: ...l design must conform to the following formats The accuracy should be as large as possible so as to ensure stable performance of platform Using one LOAD CELL Format 0 13 5000 B D A A Rated load of LOAD CELL CAP B Rated output of LOAD CELL mV V D Minimum scale N Quantity of LOAD CELL 5000 Voltage of LOAD CELL supplied by the display unit 5V 5000mV For lever LOAD CELL lever ratio should be taken int...

Page 11: ...he setting mode release the key until the screen displays CAL Step 2 Press the key to cyclically select main functional options Step 3 Press the key to cyclically select internal options Step 4 Press the key to begin further changes to the internal options after changed it is allowed to return to weighing mode by pressing the key directly If it is desired to continue to set main functional options...

Page 12: ...bled lb pound ON enabled or OFF disabled Taiwan Jin led or OFF ON enab disabled HK Jin led or OFF ON enab disabled Jin ON enabled or OFF disabled led or OFF ON enab disabled ON OFF kg Unit selection Summary It can PCS led or OFF be used to temporarily cancel those idle weighing units ON enab disabled kg kilogram g gram t ton lb pound Taiwan Jin HK Jin Init kg Power on Unit Summary Select the unit ...

Page 13: ... automatic power off after 30 minute Aut NO The scale will be a and Automatic power off setting Summary utomatically powered off within preset time if it works stably there is no any operation Aut 60 automatic power off after 60 minutes lit Aut Automatic backlight that is the backlight will not be lit unless the weight capacity is more than 9 times of minimum accuracy lit ON No backlight lit Aut a...

Page 14: ...s at the zero point the value will not be displayed until at least 4 times of accuracy is placed on Zero 4 displayed until at least 5 times of accuracy is placed on In case that the display value is at the zero point the value will not be Summary it can be used to improve zer g caused by Zero 5 displayed until at least 6 times of accuracy is placed on o point driftin environmental or other disturb...

Page 15: ...nuous signal transmission Once continuous transmission is selected only PC or Et is available when selecting among external devices PC Computer SH 24 General printer TP 24 General printer AX III Self stick type width of paper 5cm 3cm EZ2 S Self stick type width of paper 5cm 3cm Et Large LCD screen P PC External device selection Summary Support general external requirements The printer types are al...

Page 16: ... the preset lower limit but not less than 9 times of accuracy bP 3b tage checking For three s but buzzer is under mute mode bP OFF It is impossible to begin to set the upper and lower limit of weight checking Reset Restore to ex factory initial setting ON enabled Rtc OFF RTC function OFF disabled ON enabled TrA ON zero point tracking Summary It can be used to improve ze g caused by environmental o...

Page 17: ... is powered on zero symbol will appear ter the 2 Zero symbol disappears and weighing capacity 2 zero point is missed display value falls within max Press the key to clear the screen display 3 Zero symbol appears again 5 2 Ma Step Description Screen display nual Tare 1 Under power on status put container or article to be tar n and the screen will display the weight o ed on the pa f the article e g ...

Page 18: ...ill of display the value net weight 2 000kg while the net weight symbol appears again 6 Take all tared and weighed articles away from the pan 5 Pr screen display 3 Step Description e tare 1 n stat Under power o us press the key and then to enter into Pre tare function the digit to be changed will flash on the screen 2 Press the key to igit to cyclically select the d be changed 3 Press the key to c...

Page 19: ...eighed articles 6 Press down the key the screen will display 3 000kg The gross weight symbol appears to take place of the net weight symbol which indicates the weight of weighed articles plus container 7 key Press down the once again and the screen will display the net weight of weighed articles 8 Take away the container and weighed articles 5 4 Automatic Tare PAGE JADEVER http www jadever com tw ...

Page 20: ... weighing mode 5 Put container on the pan e g the container weighs 1 000kg 3 Put the article to be weighed on scale pan and the value of net weight will be figured out 4 Press the key to display gross weight containing the tared article the net weight symbol disappears and gross weight symbol is shown on the screen 5 Press down the key once again and the screen will display the value of net weight...

Page 21: ...ys the right figure then return to the weight of article and the accumulation symbol appears 3 Take away the weighed articles and return to zero status 4 Put the second article on the pan Once the steady symbol appears on the screen redo step 2 and 3 until all accumulation are finished It is allowed to accumulate for 99 times For example here we accumulate for 8 times Press the key and the screen ...

Page 22: ...ticles on the pan and press the key 4 After several seconds the screen will display the right figure which means the sampling action has been completed and it is time to begin quantity counting or percentage calculation Note This is only a simple counting function and there may be errors because the difference of the articles themselves so the more the quantity is the bigger the error may be The s...

Page 23: ... will flash on the screen 2 While shifting to NC parameter press the key and the screen will display the right figure and then begin Step 6 2 4 Press the key to cyclically select the digit to be changed press the key to cyclically increase the value of flashing digit to stipulate the value of upper limit or lower limit 5 Press the key 6 1 Redo the step 2 to 5 Once the weight checking value is set ...

Page 24: ... key to begin zero point calibration 3 Wait till the screen displays the right figure and the digit to be changed begins to flash 4 Press the key to cyclically select the digit to be changed 5 Press the key to change the weight The figure shows the weight value of the weight to be placed on 6 Put proper weight on the pan press the key and begin to conduct the weight calibration when the screen dis...

Page 25: ...the pan 2 There is interference from other articles 3 LOAD CELL failed 1 Take away the articles that result in interference 2 Replace LOAD CELL or contact service department Err3 Higher than A D resolution range FFFFF 1 A D failed 2 LOAD CELL failed Replace LOAD CELL or contact service department Err3 Lower than A D resolution range XXXXX 1 A D failed 2 LOAD CELL failed Replace LOAD CELL or contac...

Page 26: ...set OVER Exceed maximum accumulation times max 99 No more accumulation Battery symbol Battery power almost runs out Replace the battery or use AC power supply transformer Part VIII External Interface If external interface is required please select the optional RS 232 RTC board first which integrates RS 232 RTC time and date record functional module onto one circuit board so only this board can ens...

Page 27: ...three seconds 2 Circularly press key to shift to choose year month and time 3 Shift to the portion expected to be revised press to circularly select the revised digit the selected digit will flash Press to change the value 4 Press to save your setup Press to return to weighing mode 8 2 Option Output 8 2 1 Printer output 2 1 1 Parameter Setting Step Description Screen display 1 Press the key after ...

Page 28: ...t the print mode There are Pr and St modes available for selection 6 Press the key to shift to external device setting mode the screen will display PEri first and then the external device 7 Press the key to cyclically set the external devices There are SH 24 TP 24 AX III EZ2 S Godex TDP 643 BP 545 and Zebra printers available for selection 8 Press the key to return to normal weighing mode PAGE JAD...

Page 29: ...exchange 8 2 2 PC Output 2 2 1 Parameter Setting Step Description Screen display 1 Press the key after press and hold down the key release the key to enter into the setting mode release the key until the screen displays CAL 2 Press the key again to shift to RS 232 transmission function setting mode 3 Press the key to cyclically set the transmission rate 9600 4800 and 2400 4 Press the key to PAGE J...

Page 30: ...to receive weighing information via computer 1 Use the following cable to connect the scale with computer 2 Set Print Mode as Continue 3 The scale begins to continuously send information to the computer You surely have to get receiving program ready on your computer Universal 25 pin to 9 pin RS232 connecting cable 2 3 pin at one side requires exchange Note circle stands for male connector and bold...

Page 31: ...G N T W k g CR LF weight Example T W 1 000 kg N W 1 000 kg G W 2 000 kg G GROSS N NET 8 4 RS 232 Input Format Baud Rate 2400 4800 9600 Data Bit 8 Parity N None Stop Bit 1 Code ASCII The commands will be given by computer and the functional formats are as follows R READ For reading the value of weight Z ZERO For zeroing T TARE For taring PAGE JADEVER http www jadever com tw 30 ...

Page 32: ...display unit 6 screw for upright pole fixation 7 screw for support fixation 8 stud 9 upper support slot 10 channel 11 pin Installation Steps Put the cable of Load Cell on 1 upright pole mount through 2 upright pole insert 2 upright pole into the hole of 1 upright pole mount and tighten the two 6 screws PAGE JADEVER http www jadever com tw 31 ...

Page 33: ...y unit to the desired angle insert the 11 pin into the positioning hole of 4 upper support and 3 lower support Then the installation is completed Use 11 pin to regulate the angle of display unit and use 7 screw to regulate the direction of display unit 2 Unit Conversion Table 1 t 1000kg 1000000g 1 lb 453 59237g 1 Jin 500g 1 HK Liang 37 799375g 1 HK Jin 16 HK Liang 1 Taiwan Liang 37 49995g 1 Taiwan...

Page 34: ...SH 24 TP 24 Only display the weight value LE D RS232 RTC LED Display EZ RS232 RTC EZ PAGE JADEVER http www jadever com tw 33 ...

Reviews: