CONN
1
2
3
4
5
E+
E-
S+
S-
LOAD-CELL
Shield
PIN
SIGNAL
1
E+
2
E-
3
S+
4
S-
LOAD CELL
CONNECTION
5
SHIELD
Solution to overlarge LOAD-CELL output:
Solution to oversmall LOAD-CELL output:
50k~500k ohm
Add resistance
LOAD-CELL
S
S+
E
E+
-
-
Add resistance
S+
E+
E-
S-
LOAD-CELL
50k~500k ohm
PAGE
JADEVER
http:www.jadever.com.tw
4