background image

 

Content 

 

1

Introduction

………………………………………………………………………….  1 

2

Precautions

………………………………………………………………………. 

3.Product Introduction

   

3-1 Specifications & Features

…………………………………………………………. 

3-2 Front Panel

………………………………………………………………………….. 

3-2-1 Display

…………………………………………………………………………….. 

3-2-2 Keyboard

………………………………………………………………………….. 

3-3 

Rear Panel………………………………………………………………………….. 

3-

4 Power supply………………………………………………………………………... 

 
 





4. Installation

 

4-1 

Load cell connection……………………………………………………………….. 

4-2 Assembly Descript

ion of Upright Pole……………………………………………. 

 

 

5

Setting Mode

 

5-1 Maximum Weighing Capacity & Division Setting

……………………………….. 

5-2 Function Setting

……………………………………………………………………. 

5-3

Description of Parameter Values………………………………………………….. 

 
 


6. Calibration

………………………………………………………………………… 

 

11 

7

.

Operation

 

7-1 Weighing

…………………………………………………………………………….. 

7-2 Tare

………………………………………………….............................................. 

7-3 Check Weighing

……………………………………………………………………. 

7-4 Simple Counting

…………………………………………………………………… 

7-5 Accumulation, Accumulation Display and Accumulation clear

………………… 

 
 
12 
12 
13 
14 
15 

8.

 

Error message

…………………………………………………………………….. 

 
15 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for JWI-700D Series

Page 1: ...tallation 4 1 Load cell connection 4 2 Assembly Description of Upright Pole 6 6 5 Setting Mode 5 1 Maximum Weighing Capacity Division Setting 5 2 Function Setting 5 3Description of Parameter Values 7 8 9 6 Calibration 11 7 Operation 7 1 Weighing 7 2 Tare 7 3 Check Weighing 7 4 Simple Counting 7 5 Accumulation Accumulation Display and Accumulation clear 12 12 13 14 15 8 Error message 15 ...

Page 2: ...cleaning the indicator Do not immerse the indicator in water or other liquids Service should be performed by authorized personnel only 3 Product Introduction 3 1 Specifications Features Specifications Model JWI 700D JWI 700S Input sensitivity 0 2uV DIV 0 2uV DIV Input voltage range 2mV to 20mV 2mV to 20mV Load cell excitation 3 D size dry batteries 3 D size dry batteries System linearity 0 007 of ...

Page 3: ... unit switching Kg g lb oz 台斤 pcs Adjustable stand for bench scale Weight accumulation max 99 pieces Manual tare pre tare simple counting check weighing and accumulation Adjustable filtering level for weighing under various conditions Suitable for a wide range of bases and load cells Adjustable capacities resolutions and parameters Enclosed PVC dustproof cover CE approved 3 2 Front Panel 3 2 1 Dis...

Page 4: ...ight Gross weight minus Tare Symbol points at NET when Tare or Preset Tare action are done UW Symbol points at UW when calculated unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations M Symbol points at M when there is accumulation data HI LO Symbol points at HI LO when check weighing function is on FULL Charging finish CHARGE Charging...

Page 5: ...mple counting mode long press to enter sample quantity choose 1 Adds the indicated weight into accumulation memory 2 During editing returns to the higher option 3 Save the settings 1 Zeros the display within 2 of max capacity 2 Exits from certain operation without save 1 Enter parameter setting 2 Enable Disable check weighing function 3 Deletes accumulation records 1 Tares the weight of the contai...

Page 6: ...Li ion battery 3 6V 300mA adaptor Optional 1 Memory recall 2 Shift keys leftwards when inputting the value 1 Select the former record when checking the accumulation record 2 Print out when connect to the printer 3 During setting value add 1 to the current value 4 Set the upper limit of the check weighing 1 Select the later record when checking the accumulation record 2 Hold the weighing value 3 Du...

Page 7: ...acket 7 Knob pole 8 Bracket slot 9 Load cell wire Step 1 Thread the wire of the Load Cell 9 on the rod seat 1 through the upright pole 2 Insert The upright pole into the rod seat and then Lock it with two screws 5 Step 2 After threading the Load Cell wire Through the bracket 3 attach the bracket to the Upright pole and then lock it with the screw 6 Note if the load cell connector is too big to thr...

Page 8: ...After adjusting the indicator to an optimal position lock the screw 5 Setting Mode 5 1 Maximum Weighing Capacity Division Setting 1 Press and hold key UNIT and M SET while powering on the scale When the window displays CAP release the key and it enters the capacity division setting 2 Press MR or TARE to shift among CAP capacity setting DIV division setting accura resolution check 3 When the window...

Page 9: ...rn Method 2 Press M SET to free set the resolution Press MR or TARE to shift key leftward or rightward Press PRINT HI or HOLD LO to change the value Press M SAVE to save and return 6 Press ZERO ESC to return to normal weighing mode 5 2 Function Setting 1 Press and hold M SET while powering on or long press M SET under normal weighing mode to enter function setting The window displays check Setting...

Page 10: ...an or any key is pressed But auto off after N seconds N 2s 5s 10s 20s ever with no action Ever It is always on when the weights over 9e On Backlight on 3 Auto off Off Non power off 5 10 30 60 minutes 4 Unit setting onoFF select the unit pcs 斤 lboz g kg on Enable the unit off Disable the unit Note Press UNIT to choose the weighing unit Press MR or TARE to enable disable the unit 5 Zero range d0 d1 ...

Page 11: ... the upper and lower limit 9 Check Weighing buzzer beep Hi There will be a warning sound when the weight of articles exceeds the upper limit and the weight is equal or more than 20d LO There will be a warning sound when the weight of articles exceeds the lower limit and the weight is equal or more than 20 d ok There will be a warning sound when the weight of articles is between the upper and lower...

Page 12: ...ow displays CAL 2 With no load on the weighing pan press TARE to start zero point calibration is blanking at the left bottom 3 Wait till the window displays the first calibration value appears at the left bottom Note The first calibration value is default If you need to change the value do as the following Press M SET to enter the value setting Press MR or TARE to move the key leftwards or rightwa...

Page 13: ...re When weighing a sample that must be held in a container tare stores the container weight into memory 1 Under the weighing mode place the container on the weighing pan wait till stable symbol appears then press the key TARE The container is tared 2 Place the item s to be weighed into the container The weight displayed is the net weight 3 Remove all items from the weighing pan the screen displays...

Page 14: ... ZERO ESC 7 3 Check Weighing Lower limit setting 1 Begin by pressing down key HOLD LO It is now in digital inputting mode with the left most digit blinking 2 To set the value of lower limit press MR or TARE to move the key leftwards or rightwards Press PRINT HI or HOLD LO to change the value 3 Press M SET to enable disable the check weighing function 4 Press M SAVE to save the Lower limit and retu...

Page 15: ...s key UNIT to select the unit PCS 2 Press key G N the ex factory default sample quantity 10 pcs is displayed 3 Use key PRINT HI or HOLD LO to choose the sampling amount Available options are10 20 50 100 200 500 pieces 4 Put the corresponding samples on the weighing pan and then press key TARE is displayed momentarily before the display reverts to the sample quantity 5 Remove the samples and put th...

Page 16: ...The number of weighments is indicated by Auxiliary display at the left bottom XX Total accumulation XX certain accumulation Accumulation Clear To clear accumulation data total accumulation data or one of the accumulation events press key M SET while the data is displayed To exit and return to normal weighing mode press key ZERO ESC 8 Error message Error Message Problem ERR0 Exceed the zero range E...