background image

 

 

 

Page 26 of 32 

 

IS2303VSP3J  Rev-A 

Keep motor dry and covered during storage.  To avoid condensation/corrosion problems, do NOT cover or wrap pump 
with plastic film or bags. 

 

8.1.

 

Storing Pump For Winterization 

 

WARNING 

– 

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining 

pump.  Failure to disconnect power may result in serious personal injury or death. 
1.

 

Drain water level below all inlets to the pool. 

2.

 

Remove drain plugs and strainer cover from strainer housing.  (See “Parts Diagram” in section 10.1 of this manual for 

pump component locations.) 

3.

 

Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping. 

4.

 

Once the pump is fully drained of water, re-install the strainer cover and drain plugs.  Store pump in a dry area. 

9.

 

  Shaft Seal Change Instructions 

IMPORTANT SAFETY INSTRUCTIONS 

PLEASE READ AND FOLLOW ALL INSTRUCTIONS 

When servicing electrical equipment, basic safety precautions should always be observed including the following.  Failure to 
follow instructions may result in injury. 

 

     

 

WARNING

 – To reduce risk of injury, do not permit children to use this product. 

 

     Disconnect all electrical power service to pump before beginning shaft seal replacement. 

 

Only qualified personnel should attempt rotary seal replacement.  Contact your local authorized Leslie’s Dealer or service 
center if you have any questions. 

 

Refer to Figure 10.1-1 for pump component locations. 

 Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal. Foreign 
matter or improper handling will easily scratch the graphite and ceramic sealing surfaces. 

9.1.

 

Removing the Motor Assembly 

1.

 

Remove the four (4) 5/16" x 1.75" hex head bolts, which hold the motor assembly to the pump/strainer housing, using 
a 1/2" wrench or socket. 

2.

 

Slide the motor assembly out of the pump/strainer housing, exposing the diffuser. Remove the three (3) diffuser screws 
and pull the diffuser off of the seal plate to expose the impeller. 

9.2.

 

Removing the Impeller 

3.

 

To prevent the motor shaft from turning, secure using a 5/16” hex wrench on the motor shaft through the fan shroud 
on the back of the pump. 

4.

 

Remove the impeller by rotating counterclockwise. 

9.3.

 

Removing the Ceramic Seat 

5.

 

Remove the spring seal assembly and seal plate from the motor by removing the four (4) 3/8” x 1” bolts that secure it 
to the motor, using a 9/16” wrench or socket.  

6.

 

Press the ceramic seat with rubber cup out of the seal plate.  If tight, use a small screwdriver to tap seal out. 

STOP

 - Clean all recesses & parts to be reassembled.  Inspect gaskets & replace if necessary. 

9.4.

 

Seal Installation 

7.

 

Clean and lightly lubricate the motor shaft and seal recesses in the seal plate with a dilute solution of non-granulated 
liquid-type soap. Gently wipe the polished face of the ceramic seal with a soft cotton cloth.  Lubricate the rubber cup 
on the ceramic seat and press it firmly into the recess of the seal plate, with the polished ceramic surface facing out. 

8.

 

Reassemble the motor to the seal plate using the four (4) 3/8” x 1” bolts. Torque the bolts to 100 in-lbs. 

9.

 

Gently wipe the black, polished surface of the spring seal assembly with a soft cotton cloth.   

10.

 

Press the spring seal assembly onto the motor shaft, with the black polished surface facing the ceramic seat. 

Summary of Contents for JVS165S

Page 1: ...JVS165S Owner s Manual Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL...

Page 2: ...Page 2 of 32 IS2303VSP3J Rev A...

Page 3: ...nted Digital Control Interface Wiring Optional 16 5 5 Remote Stop Switch Wiring Optional 16 6 Startup Operation 17 6 1 Prior to Start Up 17 6 2 Starting Priming the Pump 17 6 3 User Interface Summary...

Page 4: ...lectric Code NEC ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS...

Page 5: ...pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on ho...

Page 6: ...manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve po...

Page 7: ...e Variable speed pump operating at 300 W Cost of electricity 0 10 per kWh Convert Watts to Kilowatts 300 W 0 3 kW 0 3 kW X 0 10 kWh 0 03 per hour Note the power consumption is greatly affected by the...

Page 8: ...is advised to place pump and filter in the shade to shield them from continuous direct heat Select a well drained area that will not flood when it rains Do NOT install pump and filter in a damp or non...

Page 9: ...shock turn OFF power to pump before working on electrical connections Fire Hazard match supply voltage to pump nameplate voltage Insure that the electrical supply available agrees with the pump s volt...

Page 10: ...ing at an appropriate flow rate to operate the other equipment as defined by the timers set in the Timer Menu See section 6 7 4 10 Remote Control Wiring Operation The 1 65 THP VS pump family can be co...

Page 11: ...nd motor drive RS485 terminal block and user interface PCB Use multi conductor jacketed cable suitable for the installation location The cable must be routed through one of the left side conduit openi...

Page 12: ...Page 12 of 32 IS2303VSP3J Rev A Figure 4 12 3 Wall Mounting the Interface...

Page 13: ...n will use the remote stop feature of the drive connect the digital input terminals to the remote stop switch as shown in the Remote Stop Wiring diagram See section 5 5 7 Wiring for remote control and...

Page 14: ...IT WILL CONTINUE RUNNING IN THE EVENT OF COMMUNICATION LOSS When inputs are activated via wire jumpers the pump will respond to a communication loss after a 4 minute delay as follows 1 No inputs conn...

Page 15: ...ON ON Aux 14 OFF OFF ON ON ON Lights Button OFF ON ON ON ON 5 3 External Relay Speed Control Wiring Optional for remote selection of pump speed Note For third party controls and Hayward controls that...

Page 16: ...atus 1 OFF OFF OFF 2 ON OFF OFF 3 OFF ON OFF 4 ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON ON The number of speeds available depends on the number of auxiliary relays used as noted below 1...

Page 17: ...to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all pump and system com...

Page 18: ...tion and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See filter owner s manual for more details 4 Remove strainer cover and fill strainer housi...

Page 19: ...on 6 6 for basic product configuration a Display Language b Set Day and Time c Speed Selection d Max Allowed Speed e Min Allowed Speed f Prime Duration g Remote Control Mode h Low Temp Operation i Low...

Page 20: ...buttons for several seconds to unlock Configuration Menu 2 Use to enter Configuration Menu 3 4 Select language for all displayed messages Move to next menu item 5 Use to change clock setting Use if cl...

Page 21: ...screen is not shown 14 Use to enable or disable password protection Move to next menu item 15 Use to set password timeout Move to next menu item Note This sets the amount of time from the last button...

Page 22: ...s being controlled by a Hayward or third party pool control the pump display can be locked by the password however the pump will respond to any and all commands being sent from the pool control Button...

Page 23: ...Timer 2 until 2 00 pm Default setting for Timer 1 is to start at 12 00 am and end at 11 45 pm When Remote Control Mode is set to Relay Control the speed for Timer 1 may be set to 0 rpm to allow the p...

Page 24: ...r status messages as well as the amount of time that has elapsed since the condition occurred See section 11 2 for more detail 6 10 Stop Resume Screen 1 2 Note When Stop Resume is pressed at any time...

Page 25: ...avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine seal assembly kit See Shaft Seal Change Instructions in this manua...

Page 26: ...tter or improper handling will easily scratch the graphite and ceramic sealing surfaces 9 1 Removing the Motor Assembly 1 Remove the four 4 5 16 x 1 75 hex head bolts which hold the motor assembly to...

Page 27: ...fuser screws and torque to 20 in lbs 9 6 Replacing the Motor Assembly 13 Slide the motor assembly with the diffuser in place into pump strainer housing being careful not to disturb the diffuser gasket...

Page 28: ...2700SAV Shaft Seal Assembly Viton 1 13 SPX2300ELB Seal Plate 1 14 SPX3200Z5PAK4 Motor Bolt 4 Pack 1 15 SPX2300GV Motor Support VSP with Base Mount Screws 1 16 SPX1600Z52 Motor Support Base Mount Screw...

Page 29: ...he strainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified repair professional You should h...

Page 30: ...f present Check ambient temperature and verify against motor nameplate 50 C 122 F Check System Drive overload Indicates that motor current is too high Check impeller diffuser shaft seal and motor for...

Page 31: ...Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequ...

Page 32: ...JACUZZI is a registered trademark of Jacuzzi Inc 2020 Jacuzzi Inc All rights reserved...