background image

 

 

 

Page 5 of 32 

 

IS2303VSP3J  Rev-A 

 

 

WARNING

 – Pool and spa components (seals, gaskets, etc.) have a finite life.  All components should be 

inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not 
securely attached. 

 

WARNING

 – 

Risk of Electric Shock.

  All electrical wiring MUST be in conformance with applicable local 

codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can shock, burn, and cause death or serious 
property damage.  To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply.  
Provide a properly located electrical receptacle.    Before working on pump or motor, turn off power supply to the pump. 

 

WARNING

 – To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit to 

prevent abuse from lawn mowers, hedge trimmers and other equipment. 

 

WARNING

 – 

Risk of Electric Shock.

  In accordance with the National Electric Code (NEC), connect only 

to a branch circuit protected by a ground-fault circuit-interrupter (GFCI).  Contact a qualified electrician if you cannot 
verify that the circuit is protected by a GFCI.  The unit must be connected only to a supply circuit that is protected by a 
ground-fault circuit-interrupter (GFCI).  Such a GFCI should be provided by the installer and should be tested on a routine 
basis.  To test the GFCI, push the test circuit button.  The GFCI should interrupt power.  Push the reset button.  Power 
should be restored.  If the GFCI fails to operate in this manner, the GFCI is defective.  If the GFCI interrupts power to the 
pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock.  Do 
not use this pump.  Disconnect the pump and have the problem corrected by a qualified service representative before 
using. 

 

WARNING

 – Failure to bond pump to pool structure will increase risk for electrocution and could result in 

injury or death.  To reduce the risk of electric shock, see installation instructions and consult a professional electrician on 
how to bond pump.  Also, contact a licensed electrician for information on local electrical codes for bonding requirements. 

Notes to electrician:

  Use a solid copper conductor, size 8 or larger.  Run a continuous wire from external bonding lug 

to reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm

2

) [No. 6 AWG (13.3 mm

2

) for Canada] solid copper bonding 

wire to the pressure wire connector provided on the pump housing and to all metal parts of swimming pool, spa, or hot 
tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of 
swimming pool, spa, or hot tub.  IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, 
grounding, bonding and other general wiring procedures. 

 

WARNING

 – 

Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers, which 

are damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following entrapment 
hazards (symbols complements of APSP): 

Hair Entrapment

 - Hair can become entangled in suction outlet cover. 

Limb Entrapment

 - A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, 

broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

 - A differential pressure applied to a large portion of the body or limbs can result in an 

entrapment.  

Evisceration/ Disembowelment

 - A negative pressure applied directly to the intestines through an unprotected suction 

outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 
evisceration/disembowelment. 

Mechanical Entrapment

 - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be 

caught in an opening of a suction outlet cover resulting in mechanical entrapment. 

 

 

 

Summary of Contents for JVS165S

Page 1: ...JVS165S Owner s Manual Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL...

Page 2: ...Page 2 of 32 IS2303VSP3J Rev A...

Page 3: ...nted Digital Control Interface Wiring Optional 16 5 5 Remote Stop Switch Wiring Optional 16 6 Startup Operation 17 6 1 Prior to Start Up 17 6 2 Starting Priming the Pump 17 6 3 User Interface Summary...

Page 4: ...lectric Code NEC ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS...

Page 5: ...pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on ho...

Page 6: ...manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve po...

Page 7: ...e Variable speed pump operating at 300 W Cost of electricity 0 10 per kWh Convert Watts to Kilowatts 300 W 0 3 kW 0 3 kW X 0 10 kWh 0 03 per hour Note the power consumption is greatly affected by the...

Page 8: ...is advised to place pump and filter in the shade to shield them from continuous direct heat Select a well drained area that will not flood when it rains Do NOT install pump and filter in a damp or non...

Page 9: ...shock turn OFF power to pump before working on electrical connections Fire Hazard match supply voltage to pump nameplate voltage Insure that the electrical supply available agrees with the pump s volt...

Page 10: ...ing at an appropriate flow rate to operate the other equipment as defined by the timers set in the Timer Menu See section 6 7 4 10 Remote Control Wiring Operation The 1 65 THP VS pump family can be co...

Page 11: ...nd motor drive RS485 terminal block and user interface PCB Use multi conductor jacketed cable suitable for the installation location The cable must be routed through one of the left side conduit openi...

Page 12: ...Page 12 of 32 IS2303VSP3J Rev A Figure 4 12 3 Wall Mounting the Interface...

Page 13: ...n will use the remote stop feature of the drive connect the digital input terminals to the remote stop switch as shown in the Remote Stop Wiring diagram See section 5 5 7 Wiring for remote control and...

Page 14: ...IT WILL CONTINUE RUNNING IN THE EVENT OF COMMUNICATION LOSS When inputs are activated via wire jumpers the pump will respond to a communication loss after a 4 minute delay as follows 1 No inputs conn...

Page 15: ...ON ON Aux 14 OFF OFF ON ON ON Lights Button OFF ON ON ON ON 5 3 External Relay Speed Control Wiring Optional for remote selection of pump speed Note For third party controls and Hayward controls that...

Page 16: ...atus 1 OFF OFF OFF 2 ON OFF OFF 3 OFF ON OFF 4 ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON ON The number of speeds available depends on the number of auxiliary relays used as noted below 1...

Page 17: ...to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all pump and system com...

Page 18: ...tion and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See filter owner s manual for more details 4 Remove strainer cover and fill strainer housi...

Page 19: ...on 6 6 for basic product configuration a Display Language b Set Day and Time c Speed Selection d Max Allowed Speed e Min Allowed Speed f Prime Duration g Remote Control Mode h Low Temp Operation i Low...

Page 20: ...buttons for several seconds to unlock Configuration Menu 2 Use to enter Configuration Menu 3 4 Select language for all displayed messages Move to next menu item 5 Use to change clock setting Use if cl...

Page 21: ...screen is not shown 14 Use to enable or disable password protection Move to next menu item 15 Use to set password timeout Move to next menu item Note This sets the amount of time from the last button...

Page 22: ...s being controlled by a Hayward or third party pool control the pump display can be locked by the password however the pump will respond to any and all commands being sent from the pool control Button...

Page 23: ...Timer 2 until 2 00 pm Default setting for Timer 1 is to start at 12 00 am and end at 11 45 pm When Remote Control Mode is set to Relay Control the speed for Timer 1 may be set to 0 rpm to allow the p...

Page 24: ...r status messages as well as the amount of time that has elapsed since the condition occurred See section 11 2 for more detail 6 10 Stop Resume Screen 1 2 Note When Stop Resume is pressed at any time...

Page 25: ...avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine seal assembly kit See Shaft Seal Change Instructions in this manua...

Page 26: ...tter or improper handling will easily scratch the graphite and ceramic sealing surfaces 9 1 Removing the Motor Assembly 1 Remove the four 4 5 16 x 1 75 hex head bolts which hold the motor assembly to...

Page 27: ...fuser screws and torque to 20 in lbs 9 6 Replacing the Motor Assembly 13 Slide the motor assembly with the diffuser in place into pump strainer housing being careful not to disturb the diffuser gasket...

Page 28: ...2700SAV Shaft Seal Assembly Viton 1 13 SPX2300ELB Seal Plate 1 14 SPX3200Z5PAK4 Motor Bolt 4 Pack 1 15 SPX2300GV Motor Support VSP with Base Mount Screws 1 16 SPX1600Z52 Motor Support Base Mount Screw...

Page 29: ...he strainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified repair professional You should h...

Page 30: ...f present Check ambient temperature and verify against motor nameplate 50 C 122 F Check System Drive overload Indicates that motor current is too high Check impeller diffuser shaft seal and motor for...

Page 31: ...Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequ...

Page 32: ...JACUZZI is a registered trademark of Jacuzzi Inc 2020 Jacuzzi Inc All rights reserved...

Reviews: