background image

J-Allure

Fixed Panels Installation

Locate the guide with the gasket.  This is the lower guide.  Remove this gasket and install on the top guide.  Position
the lower guide on the two fixed panels while they are resting on the floor in an upside down position.  Align the predrilled
holes in the guide and panels and screw together with screws and spacers (3.5x45mm self-threading).  Attach the
external extrusion of the panels to the guide with 4.2x19mm  self-threading screws.  The right and left hand fixed panels
are identified by the logo.

Invert the assembled components and install the upper guide following the same procedure as used with the lower
guide.  Caulk the top of each fixed panel.

SEALANT

LOWER
GUIDE

SCREWS WITH SPACERS (4)

SCREWS (8)
(4.2x19mm)

REMOVE
GASKET

LOGO

SEALANT

SEALANT

UPPER GUIDE

14

Summary of Contents for J-ALLURE

Page 1: ...J ALLURE Installation Operation Instructions WHIRLPOOL BATH R Luxury Bathing and Entertainment System...

Page 2: ...into any opening Do not operate this unit without the suction cover in place Thisunitmustbeconnectedonlytosupplycircuitsthatareprotectedbyagroundfaultcircuitinterrupter GFCI SuchaGFCIshould be provid...

Page 3: ...___________ 3 Framing and Support _________________________________________________________________ 4 Rough in Reference __________________________________________________________________ 5 7 Skirt In...

Page 4: ...54 1372 mm W 92 1 2 2350 mm H ELECTRICAL REQUIREMENTS BATH 115 VAC 60 Hz 15 Amp Single Phase Must be GFCI Protected PRODUCT WEIGHT 521 lb 235 kg MOTOR PUMP 115 VAC 60 Hz 10 Amp 3450 RPM Single phase F...

Page 5: ...TOOTH LOCK WASHER Quantity 6 SPACER Quantity 4 WALL ANCHOR Quantity 6 SCREW DRYWALL 8x 2 Quantity 4 SCREW SHEETMETAL 6x 1 2 Quantity 15 SCREW COVER Quantity 4 SKIRT FLAT WASHER Quantity 6 WALL ANCHOR...

Page 6: ...the bath route the steam hoses from under the shell through the cutout in the rim Unwind the speaker wires from under the bath rim on both sides When final setting the speaker wires must be routed und...

Page 7: ...eakers The third cutout is necessary to route water supply piping to the center panel and to route hoses for the steam generators to the bath The location of a 230VAC power outlet is indicated on the...

Page 8: ...ome compensation for walls out of true less than 3 16 See fixed panels installation for wall extrusions If that is the case the bath may be placed against the finished walls If more than 3 16 shims wi...

Page 9: ...SUPPLY HOT WATER SUPPLY STUD DETAIL 1 3 1 2 38 9 MIN 12 MIN 9 MIN 38 81 SEE STUD DETAIL 1 CUTOUT IN WALL 75 1 2 BATH PERIMETER STUD FOR PLUMBING 7 ELECTRICAL OUTLET 230 V FOR CENTER PANEL 1x4 NOT FOR...

Page 10: ...vided at the appropriate distance from the vertical drop centering it lengthwise with relation to the rim of the bath The faces of the side blocks provided will be oriented along a line from the cente...

Page 11: ...fy that the kit is of the proper finish In the Jacuzzi Whirlpool Bath drain overflow kit note that the waste flange strainer overflow cover and cover screws are packaged in a separate package within t...

Page 12: ...astic edge Metal tools will scratch the surface Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge Paint tar or other difficult stains can be remo...

Page 13: ...tmaybe necessarytoremovethehandheldshowerholderasshownbelow Open the door Unscrew the M6 bolt and install the two brackets Check the plumbness with the two brackets touching the wall If necessary adju...

Page 14: ...hose clamps For units with TV insert audio cables cable TV lead fan and TV power cords through the hole in drip shield Plug the power cord into the 230 VAC outlet installed previously as shown in the...

Page 15: ...re Close the door and make sure the sensor hole on the door aligns with the TV sensor If they do not align adjust the TV position till they are aligned Secure the door Reinstall hand held shower holde...

Page 16: ...d screw together with screws and spacers 3 5x45mm self threading Attach the external extrusion of the panels to the guide with 4 2x19mm self threading screws The right and left hand fixed panels are i...

Page 17: ...side wall against the fixed panel frame Make sure the wall extrusion is against the wall Check perpendicularity with a level Mark this wall extrusion position Remove left side wall and repeat the abov...

Page 18: ...wall down onto the side of the bath so that the lower frame of the wall is inserted between the bath and the wall Secure the side wall to the center panel frame with lock washers and M6 nuts With the...

Page 19: ...they must be caulked with silicone sealant not provided Seal the entire length at the bottom and from the bottom to top where the side wall moulding meets the attached extrusion Also caulk the joint b...

Page 20: ...J Allure SEALANT FIXED PANELS LOWER GUIDE Inside Caulking Caulk the joint between the lower guide and the bath 18...

Page 21: ...of rollers Making sure the bottom rollers are positioned in the bottom guide channel lift them up and tighten the locking nuts Confirm that the door slides smoothly without binding Slide the door towa...

Page 22: ...e Then carefully lift the dome and place onto the corner panel side walls and upper guide Bring the edge of the dome in contact with the front part of the upper guide Note the correct position of the...

Page 23: ...e ON one at a time Pressing the OFF button turns all functions OFF Mixer Control To adjust the temperature turn the mixer handle as shown in Figure 2 When exiting the J Allure with all functions OFF t...

Page 24: ...ecaution as these baths are not designed to hold water continuously like pools or spas If you want a unit designed to continuously hold water see your Jacuzzi Whirlpool Bath dealer for the complete li...

Page 25: ...on the bath serve as controls for the air induction system The intensity of the hydromassage whirlpool action is determined by the amount of air inducted into the water As the amount of air is increas...

Page 26: ...Whirlpool System NOTE THE WHIRLPOOL SYSTEM SHOULD BE PURGED AT LEAST TWICE A MONTH To remove accumulations of bath residue from the whirlpool system it is recommended that a whirlpool bath be purged...

Page 27: ...ing CAUTION Keep hair a minimum of 6 inches away from the suction fitting at all times when the whirl pool system is operating Hair longer than shoulder length should be secured close to the head or a...

Page 28: ...nd disconnect all plumbing Remove the SteamPro units from their mounting 3 Flush the tanks out the drain plug can be removed with an 8 mm hexagonal wrench Reinstall the steam generators Do NOT operate...

Page 29: ...J Walnut Creek CA 94596 925 938 7070 Service Support Call 925 938 7411 Jacuzzi Whirlpool Bath has obtained applicable code standards listings generally available on a national basis for products of th...

Page 30: ......

Page 31: ...use of abrasive or improper cleaners or acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising f...

Page 32: ...rawer J Walnut Creek California 94596 Call 800 288 4002 To obtain warranty replacement for factory installed components or Company supplied options and accessories manufactured and supplied by the Com...

Reviews: