For Aero Select, Laser Select, Santina Select and Solaris Select:
Electrical Conversion from 50 AMP to 30 AMP Operation
Your spa, as it comes from the factory, requires a 230 VAC, 50 AMP, 4-wire, grounded type GFCI (Ground Fault
Circuit Interrupter) protected electrical service. If you prefer, the spa can be converted to operate with a 230 VAC, 30
AMP electrical service. The conversion must be made by a qualified electrician. After conversion following this
procedure, the spa heater will automatically be turned OFF whenever either the high speed jets or the air blower is
activated.
To convert to 230 VAC, 30 AMP operation:
1. Turn OFF breaker at main electrical power.
2. Open the skirt door access panel.
3. Loosen and remove 4 screws securing the electrical cabinet cover and set them aside.
4. Move the jumper at circuit board location J8 from the 50A position to the 20A position. Refer to Figures 1 and 2.
5. Replace electrical cabinet cover and tighten the screws.
6. Test for proper operation of the GFCI before using the spa. Refer to the installation instructions for proper test
procedure.