19
CHAPTER 4 - OPERA
TION AND ADJUSTMENTS
J-600 ELECTRIC
Chemical container rinse
> Procedures
∙ Fill the chemical tank up to approximately 90%
of its capacity.
∙ Pour the chemical into the tank.
∙ Engage the tractor PTO.
ATTENTION!
The relief lever of the chemical con-
trol must be set to allow the chemi-
cal return to the tank (off) and the
suction filter valve must be with the
arrow turned to the main tank.
Use the recommended protective
clothing for this operation.
∙ The chemicals are packaged in appropriate
containers for each type of product.
∙ After emptying the containers, they must be
discarded in a safety way, in order not to poison
the man and the environment.
∙ It is very important , before any discard of
empty containers, to remove the residues of the
product that are sticked inside it and make it
useless by piercing it.
∙ Metal, plastic and glass containers must be
rinsed for decontamination.
∙ To facilitate this important operation , Jacto
has installed on its trailed sprayers a suitable
device that rinses internally the containers with
pressurized water, eliminating most of the resi-
dues.
sprinkler
stainer
valve directional
seals
fixer valve
chemical
container
chemical container
rinse nozzle
directional
valve lever
∙ Hold the chemical container over the rinse
nozzle and pull the directional valve lever to
wash inside the container.
∙ Fill up the sprayer tank with water.
NOTE:
With the chemical container over the
rinse nozzle, make circular move-
ments to reach all internal walls of
the chemical container with the wa-
ter jet for around 30 seconds.
> Chemical container rinse
close
open
1