![background image](http://html1.mh-extra.com/html/jacto/arbus-270/arbus-270_operators-manual_3181095079.webp)
5-77
5
M
A
INTE
NAN
CE
ARBUS 270
Whenever problems affect JACTO machines
fitted with piston cup-type pumps, try to ca-
tegorize the same within one the four groups
listed below.
a. Suction and boost deficiency
• No liquid comes out from the nozzles;
• No liquid is flowing back to the reservoir;
• No pressure is indicated on the pres-
sure regulator.
b. Insuficiência de pressão (falta parcial de
pressão)
• The liquid is not sprayed at the proper
pressure (A);
• The spraying angle is smaller than the
specified angle (B);
• The gauge shows lower pressure (C).
c. Pressure oscillation
• The gauge pointer is oscillating (D);
• The jet spraying angle oscillates (E).
d. Intermittence
• The gauge pointer vibrates intensely (F);
• The pressure hoses vibrate intensely;
• The jet spraying angle exhibits pul-
sating variation (G).
Problems, causes and corrections
A
E
D
F
G
C
B
Trouble-shootings