![background image](http://html1.mh-extra.com/html/jacto/arbus-270/arbus-270_operators-manual_3181095051.webp)
4-51
4
O
PE
R
A
TI
O
N
AN
D
A
D
JU
ST
M
ENT
S
ARBUS 270
Level indicator
• Placed on the right side of the operator,
the level gauge (A) has a graduated scale
that facilitates the identification of the
amount of mix in the reservoir.
• During pulverization, make sure that the
level of chemicals mix in the reservoir is
not below 50 liters so that the pump does
not operate without water.
• The package washer is assembled at the
reservoir´s opening and provides a correct
and safe discard of empty packages.
• Wash packages after use for 30 seconds,
before the residues start to dry.
• Wash the packages three times.
• For more information, check the “Opera-
tion and Regulation – Procedures for using
the package washer” item.
Package washer
NOTE:
Avoid leaving chemicals leftovers
in the reservoir or even storing
them for too long. On the last
application prepare a sufficient
amount of mix to treat whatever
harvests are left untreated.
ATTENTION!
Activation of the package washer lever should only be done after placing a contai-
ner over it. The package washer nozzle rotates, and auctioning the lever without
having a package over it could sprinkle people near the machine.
A