16
21
21
MAIN COMPONENTS OF SPRAYER
SUCTION FILTER
Located between the tank and spray pump, the suction filter is specifically designed
to prevent dirt or impurities from reaching the pump.
It has a quick shut -off valve which allows easy filter cleaning, filtering elements
changing and/or pump maintenance.
FVS - 200
CHEMICAL PUMP
The chemical pumps used in the ADVANCE and ADVANCE VORTEX sprayers have capacity
ranging from 26.41 to 39.62 gallons per minute at 540 rpm at the PTO.
CHEMICAL PUMP
MODEL
FLOW RATE
(gpm)
MAXIMUM WORKING PRESSURE
26.41
39.62
300
300
psi
kgf/cm²
Its ceramic sleeves ensure great resistance to abrasion and chemical action.
Piston cup replacement becomes easier by removing the head assembly in a quick and
simple operation, with no need to remove the pump.
JP - 100
JP - 150
JP-150
JP-100
shut-off
valve