66
MAINTENANCE
WINTER STORAGE
ATTENTION:
In areas where temperatures drop to 0° or less,
the water accumulated in the spray pump can freeze
and cause serious damage.
PROCEDURES:
- Drain the spray tank through the discharge valve (1).
- Run the sprayer for about 30 seconds at between half and low speed.
Note: To avoid damage to components, do not run the sprayer over the recommended
time.
- Disconnect the inlet hose of the auxiliary tank bypass valve (2).
- Remove the in-line filter cap (3).
- Operate the flow bypass valve lever (4) to drain the circuit.
- Reinstall the components in their place.
- Repeat this operation at the end of each working day during winter time to avoid problems
in future spray applications.
1
2
5
4
3