background image

ULB-50sc SPOT CURE  

UV LED LIGHT SOURCE

OPERATING MANUAL

Summary of Contents for MIDORI ULB-50sc

Page 1: ...ULB 50sc SPOT CURE UV LED LIGHT SOURCE OPERATING MANUAL ...

Page 2: ...iber optic light source for industrial spot curing applications where space is a premium The ULB 50sc spot cure series fiber illuminators utilize eco friendly solid state LED lighting technology exhibit instant on and electronic intensity dimming capability with long operating lifetime User interface allows either intensity or constant UV output power modes The unit can be controlled using a foots...

Page 3: ...rature Alternating Current Direct Current Manufacturer Do Not Immerse in Any Liquid Do not dispose of this product as unsorted municipal waste Prepare this product for reuse or separate collection as specified by Directive 2002 96 EC of the European Parliament and the Council of the European Union on Waste Electronic and Electrical Equipment WEEE If this product is contaminated this directive does...

Page 4: ...plications Ne pas utiliser une source de lumière à DEL directe à des fins médicales WARNING MISE EN GARDE Unit MAY BE HOT Allow to cool before handling L appareil PEUT ÊTRE CHAUD Il est important de le laisser refroidir avant d y toucher CAUTION AVERTISSEMENT Preferred operation is in the horizontal position Other operating orientations are permitted L appareil fonctionne de façon optimale à l hor...

Page 5: ...uchscreen Operation on page 7 to set the desired UV output level 6 Turn unit OFF when not in use Figure 3 7 This unit is equipped with a fiber sense interlock feature The device will not emit light unless fiber cable is completely inserted into the front adapter Please ensure fiber cable is fully seated into light port 8 To ensure consistent UV output use a 3 32 hex wrench and tighten the set scre...

Page 6: ...ice is designed to have proper forced air cooling paths to maintain thermal stable operation 2 Place in an area that provides adequate ventilation to prevent unit from overheating Do not drape the LED Light Source with cloth or objects restricting airflow 3 Airflow outlets are shown in below red arrow graphics ...

Page 7: ...eration Upon startup the USHIO logo briefly appears as well as a subtitle UV 365nm or UVV 405nm identifying the wavelength of the LED After the logo displays for 3 seconds the operator menu appears The 405nm version of the logo screen is shown below ...

Page 8: ...slider beneath that button gradually fills and the Start button is replaced with a Stop button that turns off the output This is pictured below The user can also turn the output on or off by pressing an attached footswitch The gear icon in the upper right corner will allow the user to edit their settings after entering a password if Password Lock is enabled A warning will appear if a fiber isn t d...

Page 9: ...ed using a PID loop The measured UV output is shown at the bottom of the screen as a percentage of the maximum output by default This value can be shown in watts or watts cm2 instead based on the user s settings By default this device operates in Timer Control Mode In this mode the output can be turned on or off by pressing a footswitch or the Start button on the operator menu The LED stays on for...

Page 10: ...By default this setting is disabled If the user enters the wrong password the screen will turn red and a warning reading Invalid Password will appear for 2 seconds Tapping the screen removes the error message immediately The password is 87446 USHIO on a phone keypad If the user enters the correct password they will be sent to the settings menu ...

Page 11: ...n describes either the Current or the Intensity depending on the user s settings Press this to go to the Intensity Menu The button labeled Calibration goes to the Calibration Menu where the user can calibrate their device The fourth button goes to the Control Mode Menu There the user can select what method is used to set the duration of the output The button labeled Password goes to the Password M...

Page 12: ...n or an external pedal is pressed By default this value is 10 seconds The user can use the number pad to type in an amount in seconds If a value is outside of the valid range 1 120 seconds an error message will appear for 2 seconds Tapping the screen removes this error message immediately Press Exit to return to the Settings Menu ...

Page 13: ...ck loop The UV output is continuously measured and the current to the UV LED is raised or lowered to maintain a constant power output The user can choose the desired constant output by referencing menu guidelines By default this intensity setpoint is chosen as a percentage of the maximum possible measurement For instance if the user chooses 80 as their intensity setpoint the spot cure unit will at...

Page 14: ...der to ensure that the device maintains a correct constant output in Intensity Mode The first way to perform this task is to press the Auto Calibrate button This will turn on the UV output automatically for about 5 seconds During this time a message reading Calibrating will appear followed by one reading Calibration Complete once the 5 second timer has run out The measured UV output during this ti...

Page 15: ...enu the UV output is permanently turned on This allows the user to perform a measurement with any measurement device The user can type in the measured value using this screen The Unit button lets the user toggle through several units of measurement These units are Percent Watts and Watts cm2 When Percent is selected the number buttons disappear and the setpoint is always treated as 100 instead of ...

Page 16: ...control modes Timer Control and External Control Timer Control Mode is the default setting In this mode pressing the start button on the operator menu or pressing an attached footswitch will turn on the UV output for a set amount of time Pressing the pedal start button while the UV output is active turns off the output immediately External Control Mode disables the operator menu start button Inste...

Page 17: ...lock is off the gear icon sends the user directly to the Settings page Pressing the Exit button returns to the Settings page Fiber Insertion Warning When the UV output is enabled on the operator menu the device performs a check to determine if the fiber isn t fully inserted If the fiber isn t fully inserted this warning appears and the UV is turned off Pressing Continue returns to the operator men...

Page 18: ...er DO NOT IMMERSE DO NOT RECONNECT WET 4 DO NOT plug the power source into a wall outlet until it is thoroughly dry 5 It is recommended to periodically clean the reflective optical surface near the LED Please use a soft cotton swab dipped in Isopropyl Alcohol and wipe the optic surfaces and allow to thoroughly dry prior to use USB Functionality A USB Connection can be found on the rear panel of th...

Page 19: ...r Service at Telephone 714 236 8600 Email customerservice ushio com In the event the unit stops functioning try the following steps to operate light source The power supply exhibits internal protection circuitry for user safety precautions and will shut down during certain instances This equipment has been tested to ESD conditions according IEC 61326 1 and performs to performance criterion C This ...

Page 20: ... F 20 C to 60 C Humidity 30 to 75 rh Atmospheric Pressure 700 hpa to 1060 hpa Mode of Operation Continuous Safety System Classification Class II System Pollution Degree 2 Installation Category II Electrical Ratings External Power Supply Ratings Input 100 240 V 50 60 Hz 1 4 A max Output 12 V 5 0 A Recommended PS UAI Part UPS 00 ULB 35 Power Ratings Voltage 12V DC 14V DC maximum Current 5 0 amp Batt...

Page 21: ...PS 60W 12VDC 1003881 UPC US US power cord EN60320 C7 1003880 UPC EU EU Power cord EN60320 C7 1003882 UPC UK UK Power cord EN60320 C7 1004095 UPC AU AU Power Cord EN60320 C7 5003217 UAC 04 Lumatec D LLG 5mm x 1m 5003301 UAC 05 Collimating Optic 5mm Product Ordering Information Illumination Source Type LED Custom Module UV Wavelength 365 370nm Peak Power Rating 50W UV Average LED Life 10 000 Hours B...

Page 22: ...ument to the authorized distributor agent or service representative This limited warranty does not cover the breakage or failure due to tampering misuse neglect accidents improper installation modification shipping or to improper maintenance service and cleaning procedures This limited warranty is also void if the instrument is not used in accordance with the manufacturer s recommendations or if r...

Page 23: ...Operating Manual 23 www ushio com This page is intentionally left blank ...

Page 24: ...REV0720 ULB50sc MADE IN USA 5440 Cerritos Avenue Cypress CA 90630 TEL 714 236 8600 FAX 714 229 3180 www ushio com ...