![Jacobsen F305 Operation And Maintenance Manual Download Page 33](http://html1.mh-extra.com/html/jacobsen/f305/f305_operation-and-maintenance-manual_3510625033.webp)
en-33
CONTROLS 6
6.5.3 I/O DIAGNOSTICS ___________________________________________________
These screens give access to various controller input and output Pin
functions and their state to be used for diagnostic trouble shooting.
Buttons 2 & 3
can be used to scroll between the pages,
Button 1
returns to the Service Menu.
6.5.4 SETTINGS__________________________________________________________
Within the settings Menu you will find the three options:
• Weight Transfer
• Measurement Units
• Pin
• Brightness
6.5.5 MEASUREMENT UNITS_______________________________________________
Buttons 2 & 3
move the arrow up and down the list,
Button 4
selects
parameter to be altered, then
Button 2 & 3
scroll between the unit types.
When amended as necessary
Button 1
then saves the setting.
Engine Speed
Engine Throttle Postion
Pedal B Position
Pedal A Position
0
0.0V 0%
0.0V 0%
0.0V 0%
R.P.M.
Volt - %
Volt - %
Volt - %
Cutter Hours
Fuel Level
Battery Voltage
Engine Coolant Temperature
0
0
12.0
-40
R.P.M.
°C
Volt
%
Engine Total Fuel Used
Engine Fuel Rate
Engine Torque
DPF Soot
0
0.0
-125
0
Litre
%
%
I/h
{}
Settings Menu
Weight Transfer
Measurement Units
PIN
Brightness
Measurement Units
Speed
Km/h
Pressure kPa
Volume Litre
Temperature °C
Fuel Rate
L/h