CONTROLS 4
en-27
4.5.2 Display Operating Hours ___________
To check operating hours when system power switch is in
the OFF position, press the center (Black) button.
Operating hours will be displayed for 1 minute.
Figure 4E
4.5.3 Start Up Screen __________________
The Jacobsen start up screen will display for 5 seconds
when the system power switch is turned from the OFF to
the RUN position. The software version of the controllers
is displayed under Jacobsen.
Figure 4F
4.5.4 Alarm Codes _____________________
Refer to Section 12 for a complete list of Eclipse error
codes.
4.5.5 Mower Attachment Modes__________
The Eclipse mower, when in Operator Mode, has six
mower attachment sub-modes for operation.
The values listed below for each mode are the defaults,
but they can be changed if desired in the Maintenance
Mode. Any changes made, will replace the defaults
saved for each mode, until a factory reset is selected.
The six modes are:
Mode 1 - 11 Blade Reel: Use this mode when 11 blade
reels are installed. Reel motor operation is enabled,
number of reel blades are set to 11, reel speed is set to
2200 rpm, and FOC is set to 0.16 in. (0.4064 cm).
Mode 2 - 9 Blade Reel: Use this mode when 9 blade
reels are installed. Reel motor operation is enabled,
number of reel blades are set to 9, reel speed is set to
2200 rpm, and FOC is set to 0.196 in. (0.4967 cm).
Mode 3 - Roller: This mode is used when the reels are
removed and the optional Quick Roll™ greens rollers are
installed. Reel motor operation is disabled.
Mode 4 - Verticut: This mode is used when optional
verticut mowers are installed. Reel motor operation is
enabled, 1800 rpm reel speed, and FOC is set to 0.
Mode 5 - Spiker: This mode is used when the reels are
removed and optional spiker attachments are installed.
Reel motor operation is disabled.
Mode 6 - Other: This mode is used when 7 blade reels,
or an attachment other than those listed above are
installed. Reel motor operation is enabled, reel speed is
set to 2200 rpm, and FOC is set to 0. Number of reel
blades, and FOC must be set manually.
Hours
00000.0
JACOBSEN
XXXXXXX
Start up
screen
Setting
Mode 1
Reel
Mode 2
Reel
Mode 3
Roller
Mode 4
Verticut
Mode 5
Spiker
Mode 6
Other
Reel Speed
2200 rpm
2200 rpm
0
1800 rpm
0
2200 rpm
Number of reel blades
11
9
0
0
0
0
FOC Setting
0.160 in.
(0.4064
cm)
0.196 in.
(0.4967
cm)
0
0
0
0
Reels Disabled
s
No
No
Yes
No
Yes
No
Reel Motor Direction
CCW
CCW
CCW
CCW
CCW
CCW
Maximum Mow Speed
4 mph
(6.4 kph)
4 mph
(6.4 kph)
4 mph
(6.4 kph)
4 mph
(6.4 kph)
4 mph
(6.4 kph)
4 mph
(6.4 kph)
Maximum Transport Speed
9 mph
(14.5 kph)
9 mph
(14.5 kph)
9 mph
(14.5 kph)
9 mph
(14.5 kph)
9 mph
(14.5 kph)
9 mph
(14.5 kph)
Display Units
English
English
English
English
English
English
s
This setting can not be changed in the maintenance mode. Another mower attachment mode must be selected
to enable or disable reel motors. See Maintenance mode for changing mower attachment mode.