ELECTRICAL
4181384 First Edition
4-55
4
Raise/Lower Circuit
Symptom: Lower solenoid does not energize.
Symptom: Raise solenoid does not energize.
Probable Cause
Remedy
Faulty raise/lower switch.
Test switch. (See “Joystick Test” on page 4-64.)
Faulty weight transfer switch
Test switch. (See “Rocker Switch Test” on page 4-66.)
Faulty lower solenoid.
Test solenoid. (See “Solenoid Test” on page 4-68.)
Faulty raise/lower switch 5V power supply
circuit.
Measure voltage between raise/lower switch terminal 4 and ground. Voltage must be
approximately 5 VDC.
Faulty 5V lower switch input circuit.
With the raise/lower switch in the lower position, measure voltage between control
module 5V lower switch input terminal and ground. Voltage must be approximately 5
VDC.
Faulty 12V lower solenoid output circuit.
Momentarily place the raise/lower switch in the lower position.
Measure voltage between control module 12V lower solenoid output terminal and ground.
Measure voltage between lower solenoid yel/red wire terminal and ground.
Voltage must be approximately 12 VDC.
Open lower solenoid ground circuit.
Check continuity between lower solenoid blk wire terminal and ground. Continuity must
be indicated.
Probable Cause
Remedy
Faulty raise/lower Switch.
Test switch. (See “Joystick Test” on page 4-64.)
Faulty raise solenoid.
Test solenoid. (See “Solenoid Test” on page 4-68.)
Faulty raise/lower switch 5V power supply
circuit.
Measure voltage between raise/lower switch terminal 1 and ground. Voltage must be
approximately 5 VDC.
Faulty 5V raise switch input circuit.
With the raise/lower switch in the raise position, measure voltage between control module
5V raise switch input terminal and ground. Voltage must be approximately 5 VDC.
Faulty 12V raise solenoid output circuit.
Place the raise/lower switch in the raise position.
Measure voltage between control module 12V raise solenoid output terminal and ground.
Measure voltage between raise solenoid grn/wht terminal and ground.
Voltage must be approximately 12 VDC.
Open raise solenoid ground circuit.
Check continuity between raise solenoid blk wire terminal and ground. Continuity must be
indicated.
Summary of Contents for AR3
Page 1: ...AR 3 TR 3 Trim Mowers Technical Repair Manual AR30001 AR30002 TR30001 TR30002...
Page 3: ......
Page 7: ......
Page 9: ...1 2 4181384 First Edition SAFETY 1 Page Intentionally Blank...
Page 19: ...1 12 4181384 First Edition SAFETY 1...
Page 33: ...2 14 4181384 First Edition SPECIFICATIONS AND GENERAL INFORMATION 2 Page Intentionally Blank...
Page 73: ...4 16 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 85: ...4 28 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 147: ...4 90 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 200: ...HYDRAULICS 4181384 First Edition 6 9 6 Page Intentionally Blank...
Page 249: ...6 58 4181384 First Edition HYDRAULICS 6 Page Intentionally Blank...
Page 251: ...7 2 4181384 First Edition STEERING 7 Page Intentionally Blank...
Page 264: ...STEERING 4181384 First Edition 7 15 7 Page Intentionally Blank...
Page 265: ...7 16 4181384 First Edition STEERING 7...
Page 311: ...8 46 4181384 First Edition CUTTING UNITS 8 Page Intentionally Blank...
Page 331: ...9 20 4181384 First Edition ACCESSORIES AND MISCELLANEOUS REPAIR 9 Page Intentionally Blank...
Page 340: ......
Page 342: ......