7
07610-002-23-32-AD
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
On three-phase machines, imbalanced wild leg goes to L3.
Also see the Motor Rotation section.
NOTICE
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice.
TEMPSTAR HH-E NB
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
11.2 A
19.7 A
N/A
30.9 A
33.7 A
40.0 A
230
1
60 Hz
11.2 A
21.8 A
N/A
33.0 A
35.8 A
45.0 A
208
3
60 Hz
11.2 A
11.4 A
N/A
22.6 A
25.4 A
35.0 A
230
3
60 Hz
11.2 A
12.6 A
N/A
23.8 A
26.6 A
35.0 A
460
3
60 Hz
3.0 A
6.3 A
N/A
9.3 A
10.1 A
15.0 A
TEMPSTAR HH S
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
11.2 A
N/A
N/A
11.2 A
14.0 A
25.0 A
230
1
60 Hz
11.2 A
N/A
N/A
11.2 A
14.0 A
25.0 A
208
3
60 Hz
11.2 A
N/A
N/A
11.2 A
14.0 A
25.0 A
230
3
60 Hz
11.2 A
N/A
N/A
11.2 A
14.0 A
25.0 A
460
3
60 Hz
3.0 A
N/A
N/A
3.0 A
3.8 A
15.0 A
i
i
Summary of Contents for TEMPSTAR HH S
Page 35: ...07610 002 23 32 AD 26 1 5 4 2 3 6 7 10 8 9 HOOD PARTS ...
Page 61: ...07610 002 23 32 AD 52 VER SYSTEM PARTS 18 24 23 12 11 16 17 14 21 22 20 19 27 28 29 ...
Page 67: ...07610 002 23 32 AD 58 SCHEMATICS HH E VER 208 230 V NEW RINSE TANK ...
Page 68: ...59 07610 002 23 32 AD SCHEMATICS HH E VER 460 V NEW RINSE TANK ...
Page 69: ...07610 002 23 32 AD 60 SCHEMATICS HH E VER 208 230 V OLD RINSE TANK ...
Page 70: ...61 07610 002 23 32 AD SCHEMATICS HH E VER 460 V OLD RINSE TANK ...
Page 71: ...07610 002 23 32 AD 62 SCHEMATICS NB 208 230 V ...
Page 72: ...63 07610 002 23 32 AD SCHEMATICS NB 460 V ...
Page 73: ...07610 002 23 32 AD 64 SCHEMATICS HH S 208 230 V ...
Page 74: ...65 07610 002 23 32 AD SCHEMATICS SDI OPTIONS ...
Page 75: ......