![Jackson DynaTemp Service Manual Download Page 66](http://html.mh-extra.com/html/jackson/dynatemp/dynatemp_service-manual_628871066.webp)
59
07610-004-29-29-A
ADDENDUM
EXHAUST FAN WIRING
Wiring Diagram
Terminal Board
Do NOT connect
primary load directly
to Terminal Board!
!
CAUTION
WARNING: DISCONNECT POWER TO MACHINE BEFORE SERVICING
EXHAUST FAN
CONNECTION
L1
L2
CONSTANT VOLTAGE
CONNECTION
RINSE AID DISPENSER
CONNECTION
DETERGENT
DISPENSER
CONNECTION
FAN LOAD ON TIMER OUTPUT
5A, 1/4HP, 240V AC MAX
LIVE WHEN MACHINE
POWER SWITCH IS ON
LIVE WHEN RINSE
VALVE IS OPEN
LIVE WHEN WASH
PUMP MOTOR IS ON
L1
L2
(3 AMP MAX.)
L1
L2
(3 AMP MAX.)
L1
L2
(3 AMP MAX.)
TIMER
L1
L2/N
Contactor
(customer provides)
Fuse Block
Exhaust Fan
Customer Connections
Dish Machine
MAXIMUM LOAD
1 AMP, 240/120 VAC
EXHAUST FAN
CONNECTION
CONSTANT VOLTAGE
CONNECTION
RINSE AID DISPENSER
CONNECTION
DETERGENT
DISPENSER
CONNECTION
LIVE WHEN WASH
PUMP MOTOR IS ON
LIVE WHEN RINSE
VALVE IS OPEN
LIVE WHEN MACHINE
POWER SWITCH IS ON
INPUT L1 OUTPUT TO
(EXTERNAL) EXT. RELAY
FUSE: 3 AMP SLOW-ACTING
L1 OUT L2 OUT
FUSE: 3 AMP SLOW-ACTING
L1 OUT L2 OUT
FUSE: 3 AMP SLOW-ACTING
L1 OUT L2 OUT
WARNING: DISCONNECT POWER TO MACHINE BEFORE SERVICING