4
07610-004-29-29-A
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical
service contractor that your circuit protection is adequate and meets all applicable national and local codes.
Numbers in this manual are for reference and may change without notice.
VOLTS PHASE
HZ
RINSE HEATER
RATINGS
TOTAL
AMPS
TYPICAL
ELECTRICAL CIRCUIT
208
1
50
12 kW@240 V
71 A
90 A
208
1
50
14 kW@240 V
78 A
100 A
230
1
50
12 kW@240 V
78 A
100 A
230
1
50
14 kW@240 V
86 A
110 A
NOTE: Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2.
Typical fixed-trip circuit breaker sizes as listed in the NEC (Latest
Edition).
208
3
50
12 kW@240 V
45 A
60 A
208
3
50
14 kW@240 V
49 A
70 A
230
3
50
12 kW@240 V
48 A
60 A
230
3
50
14 kW@240 V
53 A
70 A
380
3
50
12 kW@380 V
29 A
40 A
380*
3
50
14 kW@240 V
34 A
45 A
415
3
50
12 kW@415 V
26 A
35 A
415
3
50
14 kW@415 V
29 A
40 A
440
3
50
12 kW@460 V
21 A
30 A
440
3
50
14 kW@460 V
25 A
35 A
208
1
60
12 kW@240 V
69 A
90 A
208
1
60
14 kW@240 V
76 A
100 A
230
1
60
12 kW@240 V
76 A
100 A
230
1
60
14 kW@240 V
84 A
110 A
208
3
60
12 kW@240 V
43 A
60 A
208
3
60
14 kW@240 V
47 A
60 A
230
3
60
12 kW@240 V
46 A
60 A
230
3
60
14 kW@240 V
51 A
70 A
460
3
60
12 kW@480 V
22 A
30 A
460
3
60
14 kW@480 V
25 A
35 A
* This model is wired in a wye configuration for the heaters.
NOTICE
i