![Jackson AJ-64CE Installation/Operation & Technical Manual Download Page 94](http://html2.mh-extra.com/html/jackson/aj-64ce/aj-64ce_installation-operation-and-technical-manual_3193191094.webp)
SECTION 5: PARTS SECTION
86
MOTOR ASSEMBLIES
WASH MOTOR CHART
Volts
Phase Hz
Part Number
208 - 230
1
60
06105-021-70-57
200 - 230
3
60
06105-121-70-58
460
3
60
06105-121-70-58
PREWASH MOTOR CHART
Model(s)
Volts
Phase Hz
Part Number
AJ-86’s
208
1
60
06105-121-70-55
230
1
60
06105-121-70-55
208
3
60
06105-121-70-56
230
3
60
06105-121-70-56
460
3
60
06105-121-70-56
AJ-100’s
208
1
60
06105-121-70-57
230
1
60
06105-121-70-57
208
3
60
06105-121-70-58
230
3
60
06105-121-70-58
460
3
60
06105-121-70-58
POWER RINSE MOTOR CHART
Model(s)
Volts
Phase Hz
Part Number
AJ-100’s
208
1
60
06105-121-70-57
230
1
60
06105-121-70-57
208
3
60
06105-121-70-58
230
3
60
06105-121-70-58
460
3
60
06105-121-70-58
See Motor
Chart Below
Key, 3/16” x 1” Long
05700-011-89-17
Pump Plate
05700-021-71-83
Cap Screw, 3/8”-16 x 2”
05305-011-74-98
Wash Impeller
05700-031-67-45
Power Rinse Impeller (AJ-100’s)
05700-031-67-45
Prewash Impeller (AJ-86’s & AJ-100’s)
05700-031-71-78
Pump Seal
05330-011-71-98
Impellar Washer
05700-011-71-95
Bolt, 1/4”-20 x 3/4”
05305-274-04-00
Upper Support Bracket
05700-021-73-68
Lower Support Bracket
05700-021-73-71
Nut, 1/4”-20 Serrated
05310-011-66-49
Motor Mounting Gasket
05330-011-71-62
Clamp
(Not Shown)
04730-002-32-15
Summary of Contents for AJ-64CE
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 52: ...44 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 57: ...49 SECTION 4 TROUBLESHOOTING SECTION...
Page 61: ...53 SECTION 5 PARTS SECTION...
Page 121: ...113 SECTION 6 ELECTRICAL SCHEMATICS...
Page 122: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 114...
Page 123: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE SECONDARY SIDE 115...
Page 124: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 116...
Page 125: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 117...
Page 126: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 118...
Page 128: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 120...
Page 130: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 122...
Page 131: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 123...
Page 132: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 124...
Page 133: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 125...
Page 138: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 130...
Page 139: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 131...
Page 144: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 136...
Page 145: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 137...
Page 152: ...SECTION 6 ELECTRICAL SCHEMATICS CONVEYOR EXHAUST FAN HOOKUP 144...
Page 154: ......