![Jackson AJ-64CE Installation/Operation & Technical Manual Download Page 12](http://html2.mh-extra.com/html/jackson/aj-64ce/aj-64ce_installation-operation-and-technical-manual_3193191012.webp)
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS (CONTINUED)/D226 STEAM BOOSTER PARAMETERS
4
AJ-100CE MODELS
TYPICAL
TOTAL
ELECTRICAL
VOLTS
PH
HZ
AMPS
CIRCUIT
208
1
60
148 A
200 AMP
230
1
60
136 A
175 AMP
208
3
60
88 A
110 AMP
230
3
60
81 A
110 AMP
460
3
60
41 A
60 AMP
AJ-100CGP MODELS
TYPICAL
TOTAL
ELECTRICAL
VOLTS
PH
HZ
AMPS
CIRCUIT
208
1
60 28 A
35 AMP
230
1
60 28 A
35 AMP
208
3
60 19 A
25 AMP
230
3
60 19 A
25 AMP
460
3
60 10 A
15 AMP
AJ-100CS MODELS
TYPICAL
TOTAL
ELECTRICAL
VOLTS
PH
HZ
AMPS
CIRCUIT
208
1
60
28 A
35 AMP
230
1
60
28 A
35 AMP
208
3
60
18 A
25 AMP
230
3
60
18 A
25 AMP
460
3
60
9 A
15 AMP
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
D226 STEAM BOOSTER
ELECTRICAL REQUIREMENTS:
VOLTAGE (V)
208-230
FREQUENCY (HZ)
60
PHASE
SINGLE
WATER REQUIREMENTS:
INCOMING WATER TEMPERATURE (MINIMUM)
110
F
FLOW PRESSURE (PSI)
20
5
STEAM REQUIREMENTS:
INCOMING STEAM PRESSURE (PSIG)
15-25
HEAT EXCHANGER SPECIFICATIONS:*
TUBESIDE WORKING PRESSURE (PSI)
125
SHELLSIDE WORKING PRESSURE (PSI)
125
TUBESIDE HYDROSTATIC TEST PRESSURE (PSI) 250
SHELLSIDE HYDROSTATIC TEST PRESSURE (PSI)
188
MAXIMUM OPERATING TEMPERATURE
295
F
MAXIMUM SHELLSIDE STEAM PRESSURE (PSI) 125
* - Indicates typical design criteria but is subject to change
without notice. For more information, contact you authorized
Jackson service representative.
WATER OUTLET SAFETY VALVE
SET PRESSURE (PSI):
125
STEAM RELIEF VALVE SET PRESSURE (PSI):
50
Summary of Contents for AJ-64CE
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 52: ...44 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 57: ...49 SECTION 4 TROUBLESHOOTING SECTION...
Page 61: ...53 SECTION 5 PARTS SECTION...
Page 121: ...113 SECTION 6 ELECTRICAL SCHEMATICS...
Page 122: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 114...
Page 123: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE SECONDARY SIDE 115...
Page 124: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 116...
Page 125: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 117...
Page 126: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 118...
Page 128: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 120...
Page 130: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 122...
Page 131: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 123...
Page 132: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 124...
Page 133: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 125...
Page 138: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 130...
Page 139: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 131...
Page 144: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 136...
Page 145: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 137...
Page 152: ...SECTION 6 ELECTRICAL SCHEMATICS CONVEYOR EXHAUST FAN HOOKUP 144...
Page 154: ......