SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS (CONTINUED)
31
STEAM LINE CONNECTIONS:
Some machines covered in this manual are designed to use low pressure steam as a source
of heat for wash tank water. The machines come with lines by which outside source steam needs to be connected. Connect all
incoming steam lines in accordance with the steam booster manufacturer’s instructions. Ensure that all applicable codes and
regulations are adhered to. See machine data plate for information concerning steam flow pressure.
GAS CONNECTIONS:
Some machines covered in this manual are designed to use gas as an outside source of heat for wash
tank water. The machines come with connections by which an outside source needs to be connected. Connect all incoming gas
lines in accordance with the gas booster manufacturer’s instructions. Ensure that all applicable codes and regulations are
adhered to.
PLUMBING CHECK:
Slowly turn on the water supply to the machine after the incoming fill line and the drain line have been
installed. Check for any leaks and repair as required. All leaks must be repaired prior to placing the machine in operation.
ELECTRICAL POWER CONNECTION:
Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the
circuit.
The dishmachine data plate is located on the right side and to
the front of the machine. Refer to the data plate for machine
operating requirements, machine voltage, total amperage load
and serial number.
To install the incoming power lines, open the control box. Install
conduit into the pre-punched holes in the back of the control box.
Route power wires and connect to power block and grounding
lug. Install the service wires (L1, L2, and L3 (3 phase only)) to
the appropriate terminals as they are marked on the terminal
block. Install the grounding wire into the lug provided. Tighten
the connections. It is recommended that “DE-OX” or another
similar anti-oxidation agent be used on all power connections.
VOLTAGE CHECK:
Ensure that the power switch is in the OFF
position and apply power to the dishmachine. Check the incom-
ing power at the terminal block and ensure it corresponds to the
voltage listed on the data plate. If not, contact a qualified service
agency to examine the problem. Do not run the dishmachine if
the voltage is too high or too low. Shut off the service breaker
and mark it as being for the dishmachine. Advise all proper per-
sonnel of any problems and of the location of the service break-
er. Replace the control box cover and tighten down the screws.
VENTILATION OF DISHMACHINE:
The dishmachine should be located with provisions for venting into an adequate exhaust
hood or ventilation system. This is essential to permit efficient removal of the condensation exhaust. Ensure that the exhaust
system is acceptable in accordance with all applicable codes and standards.
NOTE: Any damage that is caused by steam or moisture due to improper ventilation is NOT covered under the war-
ranty.
This units covered in this manual have the following exhaust requirements:
Load End:
200 CFM
Unload End:
400 CFM
The exhaust system must be sized to handle this volume for the dishmachine to operate as it was designed to.
Incoming Power Connection
Decal showing
“L1”, “L2”, & “L3”
(3 phase models
only).
Terminal Block
Summary of Contents for AJ-64CE
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 52: ...44 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 57: ...49 SECTION 4 TROUBLESHOOTING SECTION...
Page 61: ...53 SECTION 5 PARTS SECTION...
Page 121: ...113 SECTION 6 ELECTRICAL SCHEMATICS...
Page 122: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 114...
Page 123: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE SECONDARY SIDE 115...
Page 124: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 116...
Page 125: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 117...
Page 126: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 118...
Page 128: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 120...
Page 130: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 122...
Page 131: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 123...
Page 132: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 124...
Page 133: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 125...
Page 138: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 130...
Page 139: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 131...
Page 144: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 136...
Page 145: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 137...
Page 152: ...SECTION 6 ELECTRICAL SCHEMATICS CONVEYOR EXHAUST FAN HOOKUP 144...
Page 154: ......