![Jackson AJ-64CE Installation/Operation & Technical Manual Download Page 14](http://html2.mh-extra.com/html/jackson/aj-64ce/aj-64ce_installation-operation-and-technical-manual_3193191014.webp)
Right Side
34
[864mm]
21
[533mm]
25
[635mm]
12
[307mm]
25
[635mm]
Table to Table
Over
all
Dish
Clear
ance
B
Right to Left
Dr
iv
e
Unit
Left Side
66
1 2
[1692mm]
1 2
[15mm]
84
[2134mm]
W
ith Doors Open
Rear of Machine
Legend to Dr
awing
A
-
Machine
water
inlet
3/4"
NPT,
180°
F Hi-
temp,
140°
F Low-
temp minimum
B
- E
lectrical connection
C - Dr
ain connection 1-
1/2"
NP
T
D - V
ent collar - Optional
E
-
Vent
cowl
standar
d
Note:
A
ll
vertical
dimensions
ar
e
+/-
1/2"
fr
om floor
due to adjustable
bullet feet.
1
[25mm]
4"
(102
mm)
wide
x
16"
(406
mm)
long
cutout
in
V
ent
Cowl/Splash
S
hield.
S
hipped
with
Cover
Plate.
Floor S
ink Or Dr
ain
W
ith
3"
(76
mm)
Minimum Drain Line
25
[637mm]
64
[1626mm]
72
[1829mm]
80
[2032mm]
8
[204mm]
21
[535mm]
65
1 2
[1665mm]
A
Dr
ive
Unit
Front View
75
1 2
[1915mm]
62
1 2
[1588mm]
29
[737mm]
6
1 2
[165mm]
10
[254mm]
7
[178mm]
D
E
C
4
[102mm]
8
[203mm]
60
1 4
[1528mm]
32
3 4
[833mm]
35
[891mm]
5
[127mm]
8
1 2
[218mm]
C
B
24
1 2
[622mm]
3/4"
(19
mm)
Table
Turndown
Flange
3/4"
Max
21"
(533
mm)
Rack
Rail
Height
A
bove
Dishtable
1/4"
(6
mm)
-
5/16"
(8mm)
Rack
Rail
Tub
Table
Use
S
ilicone
Sealer
B
etween Table and
Lip of Machine to P
revent Leakage
R
ec
ommended
Table
Fabrication
Note:
Tub
Will
A
ccept
a T
able F
lange
Up to 24 7/8" (632
mm)
SECTION 1: SPECIFICATION INFORMATION
AJ-64 ELECTRIC - RIGHT TO LEFT
6
Summary of Contents for AJ-64CE
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 52: ...44 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 57: ...49 SECTION 4 TROUBLESHOOTING SECTION...
Page 61: ...53 SECTION 5 PARTS SECTION...
Page 121: ...113 SECTION 6 ELECTRICAL SCHEMATICS...
Page 122: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 114...
Page 123: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ SINGLE PHASE SECONDARY SIDE 115...
Page 124: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 116...
Page 125: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 117...
Page 126: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 118...
Page 128: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ SINGLE PHASE PRIMARY SIDE 120...
Page 130: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE PRIMARY SIDE 122...
Page 131: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 208 230 VOLT 60 HZ THREE PHASE SECONDARY SIDE 123...
Page 132: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 124...
Page 133: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 64CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 125...
Page 138: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 130...
Page 139: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CE AJ 100CE 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 131...
Page 144: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE PRIMARY SIDE 136...
Page 145: ...SECTION 6 ELECTRICAL SCHEMATICS AJ 86CS AJ 100CS 460 VOLT 60 HZ THREE PHASE SECONDARY SIDE 137...
Page 152: ...SECTION 6 ELECTRICAL SCHEMATICS CONVEYOR EXHAUST FAN HOOKUP 144...
Page 154: ......