Possible Cause
Action
Drain solenoid clogged.
Remove obstruction.
Defective OFF/DRAIN switch.
Replace.
Defective motor or motor start relay.
Replace.
Defective drain solenoid.
Replace.
Defective timer.
Replace timer.
Water turned off.
Turn water on.
1/4" test cock ball valve is closed.
Open the ball valve.
Symptom
No indication of pressure.
Machine doesn't drain when "OFF/DRAIN"