![Jackson MSC 10AB-N70 Installation And Operation Manual Download Page 34](http://html1.mh-extra.com/html/jackson-msc/10ab-n70/10ab-n70_installation-and-operation-manual_3162890034.webp)
Technical Manual (07610-003-97-40)
MASTER SWITCH:
The switch interrupts all power going to the control circuit, this means that all switches
on remote controller are inoperable until master switch is turned “on”.
START SWITCH:
This switch controls the timer motor through two circuits (see electrical diagram) it is a
three-position switch, up position = start, middle position = off, down position = start. To start, flip switch
toggle in either up or down position; indicating light in center of panel will light verifying automatic cycle
has started. After cycle ends and you are ready to start a new cycle, flip toggle to opposite position.
CYCLE LIGHT:
This light comes on only when automatic cycle is in progress and extinguishes when cycle is
complete.
MANUAL WASH SWITCH:
The switch is used to by-pass the timer and operate the wash pump manually.
The wash pump will run as long as this switch is “on”. The prime purpose of this switch is to extend the
wash period for extremely soiled dishes before putting them through the normal automatic cycle. It may
also be used as an emergency back-up should the timer ever fail to operate. The required wash time is
indicated on the remote controller.
RINSE/FILL SWITCH:
This switch is spring loaded and must be held in its up position to operate. When the
switch is operated, water is allowed to fill machine through the rinse heads. It may be used as an emergency
back-up in case of timer failure for rinsing dishes.
HEAT SWITCH:
This switch applies power to the heat circuits which are composed of automatic control
devices that turn heaters on and off to maintain required temperatures.
REPLACEMENT OF SWITCHES IN REMOTE CONTROLLER:
HEAT LIGHT:
This indicating light remains on when the heater switch is in the on position.
Before working on the machine, it is important that power be turned off at the customer’s circuit breaker to
prevent the possibility of electrical shock, trip breaker to “off” position.
Remove front panel from the remote controller box by removing the four screws holding it in place. Hang the front
panel using the two right hand upper and lower screw receptacles on the control box with backside of panel facing
outward. The five switches are mounted in individual round holes with a keyway. By using a pair of pliers, or open
end wrench, it is possible to loosen the inside nut enough to allow the outside nut holding the switch to be removed
by fingers. Push switch out of hole.
(CONTINUED ON NEXT PAGE)
29
Page Created: 09-10-2012
Revised: N/A
FUNCTION OF SWITCHES & INDICATING LIGHTS
Summary of Contents for 10AB-N70
Page 8: ...Revision Letter Revision Date Made By Applicable ECNs Details...
Page 59: ...APPENDIX A DEMA Nitro Warewash Dispenser A 1...
Page 61: ...Part 1 Nitro Warewash Dispenser User s Manual...
Page 70: ...Part 2 Solid Rinse Bowl Installation Instructions...
Page 75: ...Part 3 Viking Bowl Installation Instructions...
Page 78: ...Part 4 Nitro Warewash Dispenser Training Manual...