16
NOTE: ELECTRICAL CONNECTIONS TO BE MADE DURING INSTALL. USE 14 AWG
WIRE FOR CONNECTIONS BETWEEN THE TERMINAL BOX (TB2) AND
REMOTE CONTROLLER (TB1). 14 AWG WIRE IS
NOT
INCLUDED.
ELECTRICAL CONNECTION POINTS FOR REMOTE CONTROLLER
TO ( TB2 ) TERMINAL POINT 16 ( BLK )
TO ( TB2 ) TERMINAL POINT 18 ( BLK )
TO ( TB2 ) TERMINAL POINT 20 ( BLK )
TO ( TB2 ) TERMINAL POINT 8 ( RED )
TO ( TB2 ) TERMINAL POINT 10 ( RED )
TO ( TB2 ) TERMINAL POINT 12 ( RED )
TO ( TB2 ) TERMINAL POINT 14 ( RED )
TO ( TB2 ) TERMINAL POINT 2 ( BLK )
TO ( TB2 ) TERMINAL POINT 4 ( BLK )
TO ( TB2 ) TERMINAL POINT 6 ( BLK )
L3
L2
L1
INCOMING POWER
CONNECTION
POINTS
TB1 TERMINAL BLOCK (REMOTE CONTROLLER)
TB2 TERMINAL BLOCK (DISHMACHINE TERMINAL BOX)
LEGEND
L1
L2
L3
IT1
IT2
IT3