12
/
14
3.9.3 Monitoring parameter list (press P + press foot lifter key to enter)
4 Error code
4.1 Error code list
If have Error or alarm, please check first as follows:1. Check the connection wire is connected or not; 2.
Check the machine head is matched with the control box; 3. check reset is accurate or not.
Error number
Code meaning
Solutions
Err-01
Arm shaft motor
hardware overcurrent
1. Turn off the system power, and turn it on again after 30 seconds.
2. Check whether the arm shaft motor encoder and electronic control are damaged
or in other poor conditions. If so, replace them in time.
3. If the system still does not work properly after troubleshooting and restart.
Please contact your local service provider or call 4008876858.
Err-03
System undervoltage
Disconnect the power supply of the controller and check whether the input power
supply voltage is lower than 176V. If so, please restart the controller after the
voltage returns to normal. If the voltage returns to normal, it still does not work
properly after the controller starts up. Please contact your local service provider or
call 4008876858.
Err-04
Overvoltage during
shutdown
Disconnect the controller power and check whether the input power voltage is
higher than 264V. If so, please restart the controller after the voltage returns to
normal. If the voltage returns to normal, it still does not work properly after the
controller starts up.Please contact your local service provider or call 4008876858.
Err-05
Overvoltage during
operation
Disconnect the controller power and check whether the input power voltage is
higher than 264V. If so, please restart the controller after the voltage returns to
normal. If the voltage returns to normal, it still does not work properly after the
controller starts up.Please contact your local service provider or call 4008876858.
Err-06
Electromagnet circuit
failure
1. Turn off the system power, check whether the electromagnet connection is
correct and whether there is any loose or damaged part. If so, replace it in time.
2. Unplug the electromagnet plug on the electric control to confirm whether the
electric control is normal. If the electric control is normal, please check whether
the electromagnetic circuits are damaged.
3. If the system still does not work after troubleshooting and restart.
Please contact your local service provider or call 4008876858.
Err-07
Arm shaft motor
current detection
circuit failure
Turn off the system power, and turn on the power again after 30 seconds to see
whether it can work properly. Try a few times again. If the fault occurs frequently,
please contact your local service provider or call 4008876858.
Number
Description
Number
Description
M10
Stitches account number
M23
Initial angle
M11
Pieces account number
M24
Mechanical angle
M13
Panel version number
M25
Max value for pedal forward press
M18
Main board version number for
control box
M26
Sample value for pedal back
M20
Generatrix Voltage
M28
Sample pedal value of trimming
M21
Machine speed
M30-M37 Historical Error number
M58
Stepmotor Electric Angle
M59
Stepmotor current value