Alarm system JA-60 “COMFORT”
-
17 -
MDY51306
7.2.28. Telephone line checking sequence: 9 9 x
If this function is enabled, the dialer will check regularly if the telephone line is ready to make a phone call. If the line is not
ready for more than 15 minutes, the control panel will indicate a telephone line failure (failure L). The failure will also be
indicated, if you make (or receive) a phone call or fax longer than 15 minutes.
options:
9 9 1
checking
enabled
9 9 0
checking
disabled
Factory default setting: checking disabled
7.3. Factory default RESET
If you forgot the control panel codes or you have a control panel which does not have factory default setting, perform the
following procedure:
•
disconnect the AC adapter, back up battery and wait 30 seconds.
•
reconnect the back up battery and close the control panel cover
•
press and hold the 6 key while reconnecting the AC adapter.
•
when “
−−−−
“ is displayed, enter 060 (within 10 seconds)
•
reset is confirmed with “P” (panel is in programming mode)
Note: this procedure resets the factory default settings (see table 7.1.). The Master code will be 1234, Service code 6060
and all user codes, detectors, controllers and other enrolled items will be forgotten. All telephone numbers will be erased.
The reset will not erase event memory and information about the reset will be recorded there.
Warning: if the Master code is forgotten when reset is disabled (with sequence 280), the control panel reset will be possi-
ble only by the manufacturer.
8. Possibilities to extend the system
The JA-60 is a kit, which can be tailor configured according to the size of the house or the needs of the user. See the
structure of the system in fig. 14.
q u ic k
h o m e
d o o r
c o d e
p g m
m e m
8.1 Overview of JA-60 parts