Alarm system JA-60 “COMFORT”
-
21 -
MDY51306
works as normal
ready.
gramming mode
JA60P movement detector
repeatedly triggers alarms
with no visible reason
check if there are: animals in the protected area
(mice...), sudden changes of temperature or intense
air circulation, movement of objects with temperature
of about 37°C etc.
increase detector’s immunity (DIP
SW 1 to pos. 1), change location of
the detector or use an optional sen-
sor’s lens
fault C is indicated on the
control panel
technical problem of the control panel – failure of the
power supply, blown fuse in the panel etc.
check AC adapter, backup up bat-
tery, fuses or call installer
when activated, the tele-
phone dialer calls a number
multiple times
the telephone network (mobile network) does not use
standard recognition signals and the dialer is not sure
if the connection was successful or not
for calls to GSM network store F0
after the last digit to the number
(see 7.2.22)
problem is not in this list
call installer or the distributor for advice
local hot line number:
10. Recommended Professional installer basic rules
If you install the system for a customer, you should follow these rules:
•
make a drawing of intended location of the items, keeping in mind proper protection for the intended area.
•
if the customer requests reduction of the system (price reasons etc.), ask for a written confirmation that he does not
want the particular items you recommended (to avoid blame and liability if poorly covered area is robed in the future)
•
make a professional installation and do not forget to clean and be tidy.
•
it is very important to explain to the customer all functions of the system, to teach to him or her how to program access
codes, how to test the system and how to replace batteries in the items
•
offer your regular assistance for testing and battery replacement (we recommend annually)
•
make a written report signed by the customer, that the installation was finished properly and that she or he received
your training on how to operate and test the system
11. Specifications:
control panel power
230VAC, 50Hz (110VAC, 60Hz optional)
back up battery
12V, 1,3Ah ref. 12V1K optional
back up power output
13.8V, max. 50mA (permanent load), max. 1A (10 minutes)
number of zones (detectors)
16
number of controllers (keypads) max. 8
events memory
127 latest events incl. date and time information
built in siren
118dB
working frequency
433.92 MHz (optional)
RF approved according
I-ETS 300 220
complies with
EN 50131-1, 50131-5
telephone dialer*
voice message to 4 numbers
numeric message to a Pager
digital communication to a monitoring station
approved according*
TBR21
working environment
indoor use, -10 to +40°C
•
only for control panels equipped with the telephone dialer module
User instructions of JA-60 „Comfort“
Event indicators
– informs what happened in the system. Display specifies from where the event is reported.
alarm
alarm triggered by an intruder, smoke, gas etc. See specification on the display
tamper
opened cover, damaged detector, excessive number of attempts to enter code etc. See specification on the display.
fault
power loss, lost communication with a detector etc., see specification on the display (confirm pressing key
N
)
battery
battery of the device specified on the display is low. See battery replacement below.
Display
specifies event source or mode of the control panel
event source:
1 to16
detector number
c1 to c8
controller or keypad number
C
control panel
A
wireless siren
J
sub system (other JA-60 system linked to first system)
L
telephone line
d
digital line (PC interface)
P
programming mode
U
user mode (battery replacement & testing)
H
home (partial) arming (detectors 11 to 16 are bypassed)
−−−−
waiting for more data to complete instruction
armed
continues = armed
slow blinking = exit delay