5.3. Remote control and wireless keypad testing
•
Press any button on the remote control or enter a valid code on the
wireless keypad (1234 factory default setting)
•
The control panel’s LED display will display the controller’s number (c1 to c8)
and it will make a beep (press F to select the loudness of the beep).
•
This procedure allows you to test the remote control’s working range
Fig.
12
5.4. Recording detector’s location
After successfully testing all detectors, we recommend that you to record
the location of the sensors directly on the control panel (area under the LED
display). A suitable marker for this is provided. If you need to erase your rec-
ord, use a tissue dipped in rubbing alcohol.
You can also record the location of the detectors on the user instruction
card, and in the Comlink software as well. (See software instructions)
fig.
13
6. Finishing of the installation
•
Check that all detectors and other items have their covers attached.
•
If the control panel has a built in telephone dialer, record your voice message and program the desired telephone num-
bers (see part 7.2.).
•
We recommend to set the date and time in the control panel (see part 7); The control panel stores all events to an
events list in its the internal memory, including the date and time of the event. These details from the memory can be
viewed any time in the future via a connected PC and ComLink software. The PC can also be used for convenient set-
ting of the control panel.
•
The system has a factory default setting, which allows you to use it without any other additional programming. If you
want to customize the control panel setting, see part 7.
•
Change the system Service Code to protect against unauthorized access to the programming mode (see part 7).
•
Exit programming
mode by pressing the
N
key. The control panel will then enter the disarm mode. See user instruc-
tion card for information on how to operate the system.
•
If you have troubles with your system, see the Trouble shooting table in part 9.
Note: during testing and normal operation you should be aware of the following function: if four alarms are triggered from
the same detector during the arming period, the detector will be bypassed automatically for the rest of the arming period.
This feature prevents unlimited number of alarms (and possible conflict with your neighbors!) when for example improperly
closed doors inside the house are repeatedly moved by the wind. Such a bypass of problematic detector is reset with the
disarming of the system.
This is the end of the basic installation procedure.