Alarm system JA-60 “COMFORT”
- 5 -
MDY51306
•
Open the detector’s cover by pressing the internal tab – see fig. 7
•
Attach the detector to the desired location using the two provided screws.
•
Be sure that the antenna is vertical (pointing up or down)
•
Attach the magnet with the provided screws to the moving part of the door or
window, and attach its cover. The gap between the detector and magnet should
not be wider than 5mm when the door is closed (see fig. 8)
•
Warning
: neither the detector nor the magnet should be fixed directly to a metal
surface. If there is no other choice, an insulating pad (plastic, wood etc.) 5mm
thick or more should be used under the detector and the magnet.
fig.
7
Fig.
8
•
Use DIP switch no. 1 to select if the reaction of the system to the door opening should be instant or delayed (main en-
trance door). Switch no. 2 must stay in the OFF position. See fig. 8.
•
check that all 3 terminals in the detector are connected together with short connecting loops.
•
install other JA60M magnetic detectors the same way.
•
Be sure to
leave all JA-60M detectors uncovered and without batteries installed
.
3.2. JA60P - motion detector installation
By using the provided bracket, the JA60P detector can be installed on the wall or in a corner. The recommended installation
height is from 2 to 2.5 meters above the floor. The detector’s coverage area is up to 12 meters and it has a detection angle of
120° (see fig. 11). Do not place the detector close to any heating/cooling vents or near any other object that often changes
temperature. The JA60P should not be placed near any item that generates a strong electromagnetic signal (transmitters,
electronic regulators etc.). Avoid locations that have intense air circulation.
Fig.
9