Alarm system JA-60 “COMFORT”
-
12 -
MDY51306
Note: in some locations the system can be repeatedly jammed for some period of time (near radar, TV station etc.). In
these cases the JA-60 system can work without any problems because all important data is repeated, but the jamming test
should not be enabled. The level of the signals and interference can be observed using the ComLink software's built in
oscilloscope..
7.2.8. Regular communication checking sequence: 2 7 x
The control panel will check communication regularly with all enrolled items (detectors, keypads, siren etc.) when this
function is enabled. If communication is lost with any item, the control panel will indicate the fault of this item (when armed
it will also trigger an alarm).
options:
2 7 1
checking
enabled
2 7 0
checking
disabled
Factory default setting: checking disabled
Note: in some locations with a strong radio interference (near radar, TV station etc.) the communication can be jammed
periodically. The control panel can detect such a strong interference as a temporary loss of communication with an item.
Even in this case, the JA-60 system is usually able to work without any problems, because all important data is repeated,
but the communication check should not be used.
7.2.9. Reset enabled sequence: 2 8 x
The factory default reset (see 7.3) can be disabled. This way no unauthorized future programming of the control panel will
be possible.
options:
2 8 1
reset
enabled
2 8 0
reset
disabled
Factory default setting: reset enabled
Note: if the Master or Service code is forgotten when reset is disabled, the control panel reset will be possible only by
manufacturer.
7.2.10. Enrollment of the control panel to a UC216, UC222, JA60K etc. sequence: 2 9 9
The control panel can send wireless data to output modules UC216 and UC222 (see 8.1.3.) and it can also work as a
subsystem of another JA-60 control panel.
Open the enrolling mode of the receiving device and then enter
299
and the control panel will generate the enrollment
signal.
7.2.11 No code requested for F1, F2, F3, F4 & F9 sequence: 3 0 x
If this parameter is enabled, no code is requested for functions F1, F2, F3, F4 and F9. When this parameter is disabled,
these functions can be used only when followed by a code (Master or User) – see the following table:
function / setting
300
301
arming
„code“
F 1
partial arming
F 2 „code“
F 2
door opening
F 3 „code“
F 3
memory reading
F 4 „code“
F 4
message listening
F 9 „code“
F 9
„code“ = Master or User
options:
3 0 1 no code requested
3 0 0 code requested
Factory default setting: no code requested
Note: this feature is also selectable on the JA60D wireless keypad and it is independent from the control panel setting.